Skip navigation links
A B C D E G H I L M N O P R S T U W 

A

ALARM_ALL - Static variable in class org.lsst.ccs.subsystem.refrig.RefrigMain1
Constants.
ALARM_HEATER - Static variable in class org.lsst.ccs.subsystem.refrig.RefrigMain1
Constants.

B

BK1696Device - Class in org.lsst.ccs.subsystem.refrig
Handles a B&K model 1696 power supply device.
BK1696Device() - Constructor for class org.lsst.ccs.subsystem.refrig.BK1696Device
Constructor.
BK9130Device - Class in org.lsst.ccs.subsystem.refrig
Handles a B&K model 9130 power supply device.
BK9130Device() - Constructor for class org.lsst.ccs.subsystem.refrig.BK9130Device
Constructor.
BKXLNDevice - Class in org.lsst.ccs.subsystem.refrig
Handles a B&K XLN series power supply device.
BKXLNDevice() - Constructor for class org.lsst.ccs.subsystem.refrig.BKXLNDevice
Constructor.
build() - Method in class org.lsst.ccs.subsystem.refrig.HexMain
Build phase
build() - Method in class org.lsst.ccs.subsystem.refrig.RefrigMain
Build phase
build() - Method in class org.lsst.ccs.subsystem.refrig.RefrigMain1
Build phase
build() - Method in class org.lsst.ccs.subsystem.refrig.TempControl
Start temperature control task.
build() - Method in class org.lsst.ccs.subsystem.refrig.ThermalMain
Build phase

C

canClearAlert(Alert) - Method in class org.lsst.ccs.subsystem.refrig.Compressor
Enables an alert to be cleared.
canClearAlert(Alert, AlertState) - Method in class org.lsst.ccs.subsystem.refrig.RefrigMain
Callback to clear an Alert instance.
canClearAlert(Alert, AlertState) - Method in class org.lsst.ccs.subsystem.refrig.ThermalMain
Callback to clear an Alert instance.
CHANSET_COLD - Static variable in class org.lsst.ccs.subsystem.refrig.HeaterPsDevice
Constants.
CHANSET_CRYO - Static variable in class org.lsst.ccs.subsystem.refrig.HeaterPsDevice
Constants.
checkChannel(String, int, String, String) - Method in class org.lsst.ccs.subsystem.refrig.CompSimMaq20Device
Checks a channel's parameters for validity.
checkChannel(String, int, String, String) - Method in class org.lsst.ccs.subsystem.refrig.CompSimPlutoDevice
Checks a channel's parameters for validity.
checkChannel(String, int, String, String) - Method in class org.lsst.ccs.subsystem.refrig.DL34970Device
Checks a channel's parameters for validity.
checkChannel(String, int, String, String) - Method in class org.lsst.ccs.subsystem.refrig.HeaterPsDevice
Checks a channel's parameters for validity.
checkChannel(String, int, String, String) - Method in class org.lsst.ccs.subsystem.refrig.MCCDevice
Checks a channel's parameters for validity.
checkChannel(String, int, String, String) - Method in class org.lsst.ccs.subsystem.refrig.PowerDevice
Checks a channel's parameters for validity.
checkChannel(String, int, String, String) - Method in class org.lsst.ccs.subsystem.refrig.SimDevice
Checks a channel's parameters for validity.
checkChannel(String, int, String, String) - Method in class org.lsst.ccs.subsystem.refrig.SimDevice.Power
Checks a channel's parameters for validity.
checkChannel(String, int, String, String) - Method in class org.lsst.ccs.subsystem.refrig.WUDevice
Checks a channel's parameters for validity.
checkHwLine(String, int) - Method in class org.lsst.ccs.subsystem.refrig.MCCDevice
Checks an output line number.
checkHwLine(String, int) - Method in class org.lsst.ccs.subsystem.refrig.SimDevice
Checks an output line number.
checkLimits() - Method in class org.lsst.ccs.subsystem.refrig.Compressor
Checks compressor shut-off limits.
close() - Method in class org.lsst.ccs.subsystem.refrig.CompSimMaq20Device
Closes device connection.
close() - Method in class org.lsst.ccs.subsystem.refrig.CompSimPlutoDevice
Closes device connection.
close() - Method in class org.lsst.ccs.subsystem.refrig.DL34970Device
Closes the connection.
close() - Method in class org.lsst.ccs.subsystem.refrig.GP390Device
Closes the connection.
close() - Method in class org.lsst.ccs.subsystem.refrig.HeaterPsDevice
Closes the connection.
close() - Method in class org.lsst.ccs.subsystem.refrig.MCCDevice
Closes the connection.
close() - Method in class org.lsst.ccs.subsystem.refrig.PowerDevice
Closes the connection.
close() - Method in class org.lsst.ccs.subsystem.refrig.SimDevice
Closes the connection.
close() - Method in class org.lsst.ccs.subsystem.refrig.SimDevice.Power
Closes the connection.
close() - Method in class org.lsst.ccs.subsystem.refrig.WUDevice
Closes the connection.
cmprPowerChan - Variable in class org.lsst.ccs.subsystem.refrig.Compressor
 
ColdCompressor - Class in org.lsst.ccs.subsystem.refrig
Controls a refrigeration cold compressor.
ColdCompressor() - Constructor for class org.lsst.ccs.subsystem.refrig.ColdCompressor
Constructor.
CompMaq20Device - Class in org.lsst.ccs.subsystem.refrig
Handles a compressor MAQ20 DIOL module.
CompMaq20Device() - Constructor for class org.lsst.ccs.subsystem.refrig.CompMaq20Device
 
CompPlutoDevice - Class in org.lsst.ccs.subsystem.refrig
Handles a compressor control Pluto PLC.
CompPlutoDevice() - Constructor for class org.lsst.ccs.subsystem.refrig.CompPlutoDevice
Constructor.
Compressor - Class in org.lsst.ccs.subsystem.refrig
Controls a refrigeration compressor.
Compressor(CompState) - Constructor for class org.lsst.ccs.subsystem.refrig.Compressor
Constructor.
Compressor.LimitData - Class in org.lsst.ccs.subsystem.refrig
 
Compressor.SwitchDevice - Interface in org.lsst.ccs.subsystem.refrig
 
Compressor0 - Class in org.lsst.ccs.subsystem.refrig
Implements the refrigeration compressor subsystem.
Compressor0() - Constructor for class org.lsst.ccs.subsystem.refrig.Compressor0
 
CompSimMaq20Device - Class in org.lsst.ccs.subsystem.refrig
Handles the simulated compressor MAQ20 device.
CompSimMaq20Device() - Constructor for class org.lsst.ccs.subsystem.refrig.CompSimMaq20Device
 
CompSimPlutoDevice - Class in org.lsst.ccs.subsystem.refrig
Handles the vacuum system Pluto PLC.
CompSimPlutoDevice() - Constructor for class org.lsst.ccs.subsystem.refrig.CompSimPlutoDevice
Constructor.
CONN_TYPE_NOT_CONFIG - Static variable in class org.lsst.ccs.subsystem.refrig.PowerDevice
 
connected(AgentInfo...) - Method in class org.lsst.ccs.subsystem.refrig.HexMain
Listens for the arrival of the refrigeration subsystem.
connected(AgentInfo...) - Method in class org.lsst.ccs.subsystem.refrig.ThermalMain
Listens for the arrival of the refrigeration subsystem.
connType - Variable in class org.lsst.ccs.subsystem.refrig.PowerDevice
 
controlValves() - Method in class org.lsst.ccs.subsystem.refrig.Compressor
Control the cryo valves.
CryoCompressor - Class in org.lsst.ccs.subsystem.refrig
Controls a refrigeration cold compressor.
CryoCompressor() - Constructor for class org.lsst.ccs.subsystem.refrig.CryoCompressor
Constructor.

D

DcsDevice - Class in org.lsst.ccs.subsystem.refrig
Handles a Sorensen DCS series power supply.
DcsDevice() - Constructor for class org.lsst.ccs.subsystem.refrig.DcsDevice
Constructor.
DEVC_ID_NOT_CONFIG - Static variable in class org.lsst.ccs.subsystem.refrig.PowerDevice
 
DEVC_PARM_NOT_CONFIG - Static variable in class org.lsst.ccs.subsystem.refrig.PowerDevice
 
devcId - Variable in class org.lsst.ccs.subsystem.refrig.PowerDevice
 
devcParm - Variable in class org.lsst.ccs.subsystem.refrig.PowerDevice
 
disconnecting(AgentInfo) - Method in class org.lsst.ccs.subsystem.refrig.HexMain
Listens for the departure of the refrigeration subsystem.
disconnecting(AgentInfo) - Method in class org.lsst.ccs.subsystem.refrig.ThermalMain
Listens for the departure of the refrigeration subsystem.
discPressChan - Variable in class org.lsst.ccs.subsystem.refrig.Compressor
 
discTempChan - Variable in class org.lsst.ccs.subsystem.refrig.Compressor
 
DL34970Device - Class in org.lsst.ccs.subsystem.refrig
Handles an Agilent 34970A data logger.
DL34970Device(String, String, int) - Constructor for class org.lsst.ccs.subsystem.refrig.DL34970Device
Constructor.
DL34970Device() - Constructor for class org.lsst.ccs.subsystem.refrig.DL34970Device
 

E

enableColdSection(int, boolean) - Method in class org.lsst.ccs.subsystem.refrig.HeaterPsDevice
Sets the enabled state of the outer cold channels.
enableColdSection(int, boolean) - Method in class org.lsst.ccs.subsystem.refrig.ThermalMain
Enables/disables a cold trim heater section.
enableOutput(int, boolean) - Method in class org.lsst.ccs.subsystem.refrig.PowerDevice
Enables the output.

G

getConditionState(int) - Method in class org.lsst.ccs.subsystem.refrig.CompPlutoDevice
Gets the state of a condition.
getConditionState(int) - Method in class org.lsst.ccs.subsystem.refrig.CompSimPlutoDevice
Gets the state of a condition.
getConnType() - Method in class org.lsst.ccs.subsystem.refrig.PowerDevice
Gets the connection type.
getDevcId() - Method in class org.lsst.ccs.subsystem.refrig.PowerDevice
Gets the device ID.
getDevcParm() - Method in class org.lsst.ccs.subsystem.refrig.PowerDevice
Gets the device parameter.
getIndex() - Method in class org.lsst.ccs.subsystem.refrig.Compressor
Gets the compressor index.
getLatchState(int) - Method in class org.lsst.ccs.subsystem.refrig.CompPlutoDevice
Gets the state of a latched condition.
getLatchState(int) - Method in class org.lsst.ccs.subsystem.refrig.CompSimPlutoDevice
Gets the state of a latched condition.
getMaxChannel() - Method in class org.lsst.ccs.subsystem.refrig.PowerDevice
Gets the maximum channel number.
getMinChannel() - Method in class org.lsst.ccs.subsystem.refrig.PowerDevice
Gets the minimum channel number.
getOutput(int) - Method in class org.lsst.ccs.subsystem.refrig.HeaterPsDevice
Gets the output state.
getOutput(int) - Method in class org.lsst.ccs.subsystem.refrig.PowerDevice
Gets the output state.
getOutput(int) - Method in class org.lsst.ccs.subsystem.refrig.SimDevice.Power
Gets the power supply output state.
getPowerChannel() - Method in class org.lsst.ccs.subsystem.refrig.TempControl
Gets the power channel,
getPowerDevice() - Method in class org.lsst.ccs.subsystem.refrig.TempControl
Gets the power device,
getState() - Method in class org.lsst.ccs.subsystem.refrig.Compressor
Gets the compressor state.
getSystemState() - Method in class org.lsst.ccs.subsystem.refrig.Compressor0
Gets the state of the refrigeration module.
getSystemState() - Method in class org.lsst.ccs.subsystem.refrig.HexMain
Gets the state of the heat exchanger module.
getSystemState() - Method in class org.lsst.ccs.subsystem.refrig.RefrigMain
Gets the state of the refrigeration module.
getSystemState() - Method in class org.lsst.ccs.subsystem.refrig.RefrigMain1
Gets the full state of the refrigeration module.
getSystemState() - Method in class org.lsst.ccs.subsystem.refrig.ThermalMain
Gets the state of the thermal control system.
GP390Device - Class in org.lsst.ccs.subsystem.refrig
Handles an MKS GP390 vacuum gauge.
GP390Device(String, int) - Constructor for class org.lsst.ccs.subsystem.refrig.GP390Device
Constructor.
GP390Device() - Constructor for class org.lsst.ccs.subsystem.refrig.GP390Device
 

H

HeaterPsDevice - Class in org.lsst.ccs.subsystem.refrig
Handles a SLAC heater power supply.
HeaterPsDevice() - Constructor for class org.lsst.ccs.subsystem.refrig.HeaterPsDevice
Constructor.
HexMain - Class in org.lsst.ccs.subsystem.refrig
Implements the refrigeration heat exchanger monitoring subsystem.
HexMain() - Constructor for class org.lsst.ccs.subsystem.refrig.HexMain
Constructor.

I

initChannel(int, int, int) - Method in class org.lsst.ccs.subsystem.refrig.DL34970Device
Initializes a channel.
initChannel(String, int, int, int, int) - Method in class org.lsst.ccs.subsystem.refrig.MCCDevice
Initializes a channel.
initChannel(int, int, int) - Method in class org.lsst.ccs.subsystem.refrig.SimDevice
Initializes a channel.
initDevice() - Method in class org.lsst.ccs.subsystem.refrig.CompSimMaq20Device
Performs basic initialization.
initDevice() - Method in class org.lsst.ccs.subsystem.refrig.CompSimPlutoDevice
Performs basic initialization.
initDevice() - Method in class org.lsst.ccs.subsystem.refrig.DL34970Device
Performs configuration.
initDevice() - Method in class org.lsst.ccs.subsystem.refrig.GP390Device
Performs configuration.
initDevice() - Method in class org.lsst.ccs.subsystem.refrig.HeaterPsDevice
Performs configuration.
initDevice() - Method in class org.lsst.ccs.subsystem.refrig.MCCDevice
Performs configuration.
initDevice() - Method in class org.lsst.ccs.subsystem.refrig.PowerDevice
Performs configuration.
initDevice() - Method in class org.lsst.ccs.subsystem.refrig.SimDevice
Performs configuration.
initDevice() - Method in class org.lsst.ccs.subsystem.refrig.SimDevice.Power
Performs configuration.
initDevice() - Method in class org.lsst.ccs.subsystem.refrig.WUDevice
Performs configuration.
initialize() - Method in class org.lsst.ccs.subsystem.refrig.CompSimMaq20Device
Performs full initialization.
initialize() - Method in class org.lsst.ccs.subsystem.refrig.CompSimPlutoDevice
Performs full initialization.
initialize() - Method in class org.lsst.ccs.subsystem.refrig.DL34970Device
Performs full initialization.
initialize() - Method in class org.lsst.ccs.subsystem.refrig.GP390Device
Performs full initialization.
initialize() - Method in class org.lsst.ccs.subsystem.refrig.HeaterPsDevice
Performs full initialization.
initialize() - Method in class org.lsst.ccs.subsystem.refrig.MCCDevice
Performs full initialization.
initialize() - Method in class org.lsst.ccs.subsystem.refrig.PowerDevice
Performs full initialization.
initialize() - Method in class org.lsst.ccs.subsystem.refrig.SimDevice
Performs full initialization.
initialize() - Method in class org.lsst.ccs.subsystem.refrig.SimDevice.Power
Performs basic initialization.
initialize() - Method in class org.lsst.ccs.subsystem.refrig.WUDevice
Performs basic initialization.
isConditionActive(int) - Method in class org.lsst.ccs.subsystem.refrig.CompPlutoDevice
Gets whether a condition is active.
isEnabled(int) - Method in class org.lsst.ccs.subsystem.refrig.PowerDevice
Gets the enabled state.
isHwLineSet(int) - Method in class org.lsst.ccs.subsystem.refrig.MCCDevice
Gets the set state of an output line.
isHwLineSet(int) - Method in class org.lsst.ccs.subsystem.refrig.SimDevice
Gets the set state of an output line.
isLatchActive(int) - Method in class org.lsst.ccs.subsystem.refrig.CompPlutoDevice
Gets whether a latched condition is active.
isLatchLatched(int) - Method in class org.lsst.ccs.subsystem.refrig.CompPlutoDevice
Gets whether a latched condition is latched.
isLatchWarning(int) - Method in class org.lsst.ccs.subsystem.refrig.CompPlutoDevice
Gets whether a latched condition is in warning state.
isSwitchOn(int) - Method in class org.lsst.ccs.subsystem.refrig.CompMaq20Device
Gets the on state of a switch.
isSwitchOn(int) - Method in class org.lsst.ccs.subsystem.refrig.CompPlutoDevice
Gets the on state of a switch.
isSwitchOn(int) - Method in interface org.lsst.ccs.subsystem.refrig.Compressor.SwitchDevice
 
isSwitchOn(int) - Method in class org.lsst.ccs.subsystem.refrig.CompSimMaq20Device
Gets the on state of a switch.
isSwitchOn(int) - Method in class org.lsst.ccs.subsystem.refrig.CompSimPlutoDevice
Gets the on state of a switch.

L

LimitData() - Constructor for class org.lsst.ccs.subsystem.refrig.Compressor.LimitData
 
liquidTempChan - Variable in class org.lsst.ccs.subsystem.refrig.Compressor
 
loadNamedConfig(String) - Method in class org.lsst.ccs.subsystem.refrig.RefrigMain1
Loads a named refrigeration configuration.

M

maxCurrent - Variable in class org.lsst.ccs.subsystem.refrig.PowerDevice
 
MCCDevice - Class in org.lsst.ccs.subsystem.refrig
Handles a Measurement Computing DAQ box.
MCCDevice(String, String) - Constructor for class org.lsst.ccs.subsystem.refrig.MCCDevice
Constructor.
MCCDevice() - Constructor for class org.lsst.ccs.subsystem.refrig.MCCDevice
 
MON_TYPE_CURRENT - Static variable in class org.lsst.ccs.subsystem.refrig.PowerDevice
 
MON_TYPE_POWER - Static variable in class org.lsst.ccs.subsystem.refrig.PowerDevice
 
MON_TYPE_VOLTAGE - Static variable in class org.lsst.ccs.subsystem.refrig.PowerDevice
 
mTypeMap - Static variable in class org.lsst.ccs.subsystem.refrig.PowerDevice
 

N

NETWORK_CONN_INVALID - Static variable in class org.lsst.ccs.subsystem.refrig.PowerDevice
 
NUM_COLD_SWITCHES - Static variable in class org.lsst.ccs.subsystem.refrig.CompMaq20Device
Constants.
NUM_COLD_SWITCHES - Static variable in class org.lsst.ccs.subsystem.refrig.CompPlutoDevice
Constants.
NUM_CRYO_SWITCHES - Static variable in class org.lsst.ccs.subsystem.refrig.CompMaq20Device
Constants.
NUM_CRYO_SWITCHES - Static variable in class org.lsst.ccs.subsystem.refrig.CompPlutoDevice
Constants.

O

onStatusMessage(StatusMessage) - Method in class org.lsst.ccs.subsystem.refrig.HexMain
Handles refrigeration status messages.
onStatusMessage(StatusMessage) - Method in class org.lsst.ccs.subsystem.refrig.ThermalMain
Handles refrigeration status messages.
org.lsst.ccs.subsystem.refrig - package org.lsst.ccs.subsystem.refrig
 

P

phaseSepTempChan - Variable in class org.lsst.ccs.subsystem.refrig.Compressor
 
postInit() - Method in class org.lsst.ccs.subsystem.refrig.Compressor
Initializes the compressor control.
postInit() - Method in class org.lsst.ccs.subsystem.refrig.Compressor0
Initializes the refrigeration subsystem.
postInit() - Method in class org.lsst.ccs.subsystem.refrig.HexMain
Initializes the subsystem.
postInit() - Method in class org.lsst.ccs.subsystem.refrig.RefrigMain
Initializes the refrigeration subsystem.
postInit() - Method in class org.lsst.ccs.subsystem.refrig.RefrigMain1
Initializes the refrigeration subsystem.
postInit() - Method in class org.lsst.ccs.subsystem.refrig.TempControl
Initializes the parameters.
postInit() - Method in class org.lsst.ccs.subsystem.refrig.ThermalMain
Initializes the thermal subsystem.
postStart() - Method in class org.lsst.ccs.subsystem.refrig.Compressor0
Starts the subsystem.
postStart() - Method in class org.lsst.ccs.subsystem.refrig.HexMain
Starts the subsystem.
postStart() - Method in class org.lsst.ccs.subsystem.refrig.RefrigMain
Starts the subsystem.
postStart() - Method in class org.lsst.ccs.subsystem.refrig.RefrigMain1
Starts the subsystem.
postStart() - Method in class org.lsst.ccs.subsystem.refrig.ThermalMain
Starts the subsystem.
Power() - Constructor for class org.lsst.ccs.subsystem.refrig.SimDevice.Power
Constructor.
PowerDevice - Class in org.lsst.ccs.subsystem.refrig
Defines a power supply interface.
PowerDevice(String, PowerSupplyDriver, int, int, int) - Constructor for class org.lsst.ccs.subsystem.refrig.PowerDevice
Constructor.
PowerDevice.PowerState - Class in org.lsst.ccs.subsystem.refrig
Inner class for saving the power state of a channel.
PowerState() - Constructor for class org.lsst.ccs.subsystem.refrig.PowerDevice.PowerState
 
processAlarm(int, int, String, String) - Method in class org.lsst.ccs.subsystem.refrig.Compressor0
Handles alarm events.
processAlarm(int, int, String, String) - Method in class org.lsst.ccs.subsystem.refrig.RefrigMain1
Handles alarm events.
processData(double[]) - Method in class org.lsst.ccs.subsystem.refrig.WUDevice
Receives data periodically from the WattsUp? meter.
ProtPlutoDevice - Class in org.lsst.ccs.subsystem.refrig
Handles (minimally) a protection Pluto PLC system.
ProtPlutoDevice() - Constructor for class org.lsst.ccs.subsystem.refrig.ProtPlutoDevice
Constructor.
psd - Variable in class org.lsst.ccs.subsystem.refrig.PowerDevice
 

R

readChannel(int, int) - Method in class org.lsst.ccs.subsystem.refrig.CompSimMaq20Device
Reads a channel.
readChannel(int, int) - Method in class org.lsst.ccs.subsystem.refrig.CompSimPlutoDevice
Reads a channel.
readChannel(int, int) - Method in class org.lsst.ccs.subsystem.refrig.DL34970Device
Reads a channel.
readChannel(int, int) - Method in class org.lsst.ccs.subsystem.refrig.GP390Device
Reads a channel.
readChannel(int, int) - Method in class org.lsst.ccs.subsystem.refrig.HeaterPsDevice
Reads a channel.
readChannel(int, int) - Method in class org.lsst.ccs.subsystem.refrig.MCCDevice
Reads a channel.
readChannel(int, int) - Method in class org.lsst.ccs.subsystem.refrig.PowerDevice
Reads a channel.
readChannel(int, int) - Method in class org.lsst.ccs.subsystem.refrig.SimDevice.Power
Reads a channel.
readChannel(int, int) - Method in class org.lsst.ccs.subsystem.refrig.SimDevice
Reads a channel.
readChannel(int, int) - Method in class org.lsst.ccs.subsystem.refrig.WUDevice
Reads a channel.
readChannelGroup() - Method in class org.lsst.ccs.subsystem.refrig.CompSimMaq20Device
Reads all referenced channels.
readChannelGroup() - Method in class org.lsst.ccs.subsystem.refrig.CompSimPlutoDevice
Reads all referenced channels.
readChannelGroup() - Method in class org.lsst.ccs.subsystem.refrig.DL34970Device
Reads grouped channels.
readChannelGroup() - Method in class org.lsst.ccs.subsystem.refrig.HeaterPsDevice
Reads all heater channels as a group.
readChannelGroup() - Method in class org.lsst.ccs.subsystem.refrig.PowerDevice
Initializes voltages and currents as unread.
readCurrent(int) - Method in class org.lsst.ccs.subsystem.refrig.HeaterPsDevice
Reads the current.
readCurrent(int) - Method in class org.lsst.ccs.subsystem.refrig.PowerDevice
Reads the current.
readCurrent(int) - Method in class org.lsst.ccs.subsystem.refrig.SimDevice.Power
Gets the power supply current.
readVoltage(int) - Method in class org.lsst.ccs.subsystem.refrig.HeaterPsDevice
Reads the voltage.
readVoltage(int) - Method in class org.lsst.ccs.subsystem.refrig.PowerDevice
Reads the voltage.
readVoltage(int) - Method in class org.lsst.ccs.subsystem.refrig.SimDevice.Power
Gets the power supply voltage.
RefrigMain - Class in org.lsst.ccs.subsystem.refrig
Implements the refrigeration compressor subsystem.
RefrigMain() - Constructor for class org.lsst.ccs.subsystem.refrig.RefrigMain
Constructor.
RefrigMain1 - Class in org.lsst.ccs.subsystem.refrig
Implements the basic refrigeration subsystem.
RefrigMain1() - Constructor for class org.lsst.ccs.subsystem.refrig.RefrigMain1
 
reset() - Method in class org.lsst.ccs.subsystem.refrig.Compressor0
Resets the latches.
reset() - Method in class org.lsst.ccs.subsystem.refrig.TempControl
Resets the controller.
resetLatches() - Method in class org.lsst.ccs.subsystem.refrig.CompPlutoDevice
Resets all latched conditions.
resetLatches() - Method in class org.lsst.ccs.subsystem.refrig.Compressor
Resets the latches.
resetLatches() - Method in class org.lsst.ccs.subsystem.refrig.CompSimPlutoDevice
Resets all latches.
restart() - Method in class org.lsst.ccs.subsystem.refrig.TempControl
Restarts the control loop.

S

saveNamedConfig(String) - Method in class org.lsst.ccs.subsystem.refrig.RefrigMain1
Saves a named refrigeration configuration.
setAlarmDisabled(int) - Method in class org.lsst.ccs.subsystem.refrig.RefrigMain1
Sets the alarm disabled state on or off.
setAuxHeaterPower(int, double) - Method in class org.lsst.ccs.subsystem.refrig.ThermalMain
Sets an aux heater power value.
setAuxHeaterState(int, int) - Method in class org.lsst.ccs.subsystem.refrig.ThermalMain
Sets an aux heater state.
setClosed() - Method in class org.lsst.ccs.subsystem.refrig.WUDevice
Changes the WattsUp? meter open state.
setCmprPowerDelayLimit(double) - Method in class org.lsst.ccs.subsystem.refrig.Compressor
Sets the compressor power delayed limit.
setCmprPowerDelayTime(int) - Method in class org.lsst.ccs.subsystem.refrig.Compressor
Sets the compressor power delay.
setCmprPowerEnable(int, int) - Method in class org.lsst.ccs.subsystem.refrig.RefrigMain1
Sets the power state of a compressor.
setCmprPowerImmedLimit(double) - Method in class org.lsst.ccs.subsystem.refrig.Compressor
Sets the compressor power immediate limit.
setCompPowerEnable(int) - Method in class org.lsst.ccs.subsystem.refrig.Compressor0
Sets the compressor power state.
setCondition(int, boolean) - Method in class org.lsst.ccs.subsystem.refrig.CompSimPlutoDevice
 
setCurrent(int, double) - Method in class org.lsst.ccs.subsystem.refrig.HeaterPsDevice
Sets the current.
setCurrent(int, double) - Method in class org.lsst.ccs.subsystem.refrig.PowerDevice
Sets the current.
setCurrent(int, double) - Method in class org.lsst.ccs.subsystem.refrig.SimDevice.Power
Sets the power supply current.
setDiscPressDelayLimit(double) - Method in class org.lsst.ccs.subsystem.refrig.Compressor
Sets the discharge pressure delayed limit.
setDiscPressDelayTime(int) - Method in class org.lsst.ccs.subsystem.refrig.Compressor
Sets the discharge pressure delay.
setDiscPressImmedLimit(double) - Method in class org.lsst.ccs.subsystem.refrig.Compressor
Sets the discharge pressure immediate limit.
setDiscTempDelayLimit(double) - Method in class org.lsst.ccs.subsystem.refrig.Compressor
Sets the discharge temperature delayed limit.
setDiscTempDelayTime(int) - Method in class org.lsst.ccs.subsystem.refrig.Compressor
Sets the discharge temperature delay.
setDiscTempImmedLimit(double) - Method in class org.lsst.ccs.subsystem.refrig.Compressor
Sets the discharge temperature immediate limit.
setHeaterControl(int) - Method in class org.lsst.ccs.subsystem.refrig.RefrigMain1
Sets the heater control state.
setHeaterPower(double) - Method in class org.lsst.ccs.subsystem.refrig.RefrigMain1
Sets the heater power value.
setHeaterPowerEnable(int) - Method in class org.lsst.ccs.subsystem.refrig.Compressor0
Sets the heater power state.
setHeaterPowerEnable(int) - Method in class org.lsst.ccs.subsystem.refrig.RefrigMain1
Sets the heater power enable state.
setHwLine(int, boolean) - Method in class org.lsst.ccs.subsystem.refrig.MCCDevice
Sets an output line on or off.
setHwLine(int, boolean) - Method in class org.lsst.ccs.subsystem.refrig.SimDevice
Sets an output line on or off.
setIndex(int) - Method in class org.lsst.ccs.subsystem.refrig.Compressor
Sets the compressor index.
setLatchActive(int) - Method in class org.lsst.ccs.subsystem.refrig.CompSimPlutoDevice
 
setLatchLatched(int) - Method in class org.lsst.ccs.subsystem.refrig.CompSimPlutoDevice
 
setLatchWarning(int) - Method in class org.lsst.ccs.subsystem.refrig.CompSimPlutoDevice
 
setLiquidTempDelayLimit(double) - Method in class org.lsst.ccs.subsystem.refrig.Compressor
Sets the liquid temperature delayed limit.
setLiquidTempDelayTime(int) - Method in class org.lsst.ccs.subsystem.refrig.Compressor
Sets the liquid temperature delay.
setLiquidTempImmedLimit(double) - Method in class org.lsst.ccs.subsystem.refrig.Compressor
Sets the liquid temperature immediate limit.
setLoadFract(double) - Method in class org.lsst.ccs.subsystem.refrig.SimDevice
Sets the load power fraction
setLoadTemp(double) - Method in class org.lsst.ccs.subsystem.refrig.RefrigMain1
Sets the load temperature value.
setOnline(boolean) - Method in class org.lsst.ccs.subsystem.refrig.PowerDevice
Sets the online state.
setOutput(int, boolean) - Method in class org.lsst.ccs.subsystem.refrig.HeaterPsDevice
Sets the output state of a set of channels.
setOutput(int, boolean) - Method in class org.lsst.ccs.subsystem.refrig.PowerDevice
Sets the output state.
setOutput(int, boolean) - Method in class org.lsst.ccs.subsystem.refrig.SimDevice.Power
Sets the power supply output state.
setPhaseSepTempDelayLimit(double) - Method in class org.lsst.ccs.subsystem.refrig.Compressor
Sets the phase separator temperature delayed limit.
setPhaseSepTempDelayTime(int) - Method in class org.lsst.ccs.subsystem.refrig.Compressor
Sets the phase separator temperature delay.
setPlateTemperature(int, double) - Method in class org.lsst.ccs.subsystem.refrig.ThermalMain
Sets a plate temperature value.
setPower(int, double) - Method in class org.lsst.ccs.subsystem.refrig.PowerDevice
Sets the power.
setPowered(boolean) - Method in class org.lsst.ccs.subsystem.refrig.WUDevice
Changes the WattsUp? meter powered state.
setSuctTempImmedLimit(double) - Method in class org.lsst.ccs.subsystem.refrig.Compressor
Sets the suction temperature immediate limit.
setSwitchOn(int, boolean) - Method in class org.lsst.ccs.subsystem.refrig.CompMaq20Device
Sets a switch on or off.
setSwitchOn(int, boolean) - Method in class org.lsst.ccs.subsystem.refrig.CompPlutoDevice
Sets a switch on or off.
setSwitchOn(int, boolean) - Method in class org.lsst.ccs.subsystem.refrig.Compressor
Command to turn a switch on or off..
setSwitchOn(int, boolean) - Method in interface org.lsst.ccs.subsystem.refrig.Compressor.SwitchDevice
 
setSwitchOn(int, boolean) - Method in class org.lsst.ccs.subsystem.refrig.CompSimMaq20Device
Sets a switch on or off.
setSwitchOn(int, boolean) - Method in class org.lsst.ccs.subsystem.refrig.CompSimPlutoDevice
Sets a switch on or off.
setTemp(double) - Method in class org.lsst.ccs.subsystem.refrig.TempControl
Sets the target temperature.
setTrimHeaterPower(int, double) - Method in class org.lsst.ccs.subsystem.refrig.ThermalMain
Sets a trim heater power value.
setTrimHeaterState(int, int) - Method in class org.lsst.ccs.subsystem.refrig.ThermalMain
Sets a trim heater state.
setType(int) - Method in class org.lsst.ccs.subsystem.refrig.CompMaq20Device
Sets the compressor type.
setType(int) - Method in class org.lsst.ccs.subsystem.refrig.CompPlutoDevice
Sets the compressor type.
setType(int) - Method in class org.lsst.ccs.subsystem.refrig.CompSimMaq20Device
Sets the compressor type.
setType(int) - Method in class org.lsst.ccs.subsystem.refrig.CompSimPlutoDevice
Sets the compressor type.
setUpdatePeriod(int) - Method in class org.lsst.ccs.subsystem.refrig.Compressor0
Sets the monitor update period.
setUpdatePeriod(int) - Method in class org.lsst.ccs.subsystem.refrig.HexMain
Sets the monitor update period.
setUpdatePeriod(int) - Method in class org.lsst.ccs.subsystem.refrig.RefrigMain
Sets the monitor update period.
setUpdatePeriod(int) - Method in class org.lsst.ccs.subsystem.refrig.RefrigMain1
Sets the monitor update period.
setUpdatePeriod(int) - Method in class org.lsst.ccs.subsystem.refrig.ThermalMain
Sets the monitor update period.
setVoltage(int, double) - Method in class org.lsst.ccs.subsystem.refrig.HeaterPsDevice
Sets the voltage.
setVoltage(int, double) - Method in class org.lsst.ccs.subsystem.refrig.PowerDevice
Sets the voltage.
setVoltage(int, double) - Method in class org.lsst.ccs.subsystem.refrig.SimDevice.Power
Sets the power supply voltage.
SimDevice - Class in org.lsst.ccs.subsystem.refrig
Simulates the refrigeration hardware.
SimDevice(String, String) - Constructor for class org.lsst.ccs.subsystem.refrig.SimDevice
Constructor.
SimDevice() - Constructor for class org.lsst.ccs.subsystem.refrig.SimDevice
 
SimDevice.Power - Class in org.lsst.ccs.subsystem.refrig
Inner class to simulate power supply device with attached load.
start(double) - Method in class org.lsst.ccs.subsystem.refrig.TempControl
Starts the control loop.
stop() - Method in class org.lsst.ccs.subsystem.refrig.TempControl
Stops the control loop.
suctTempChan - Variable in class org.lsst.ccs.subsystem.refrig.Compressor
 
SW_BYPASS_VALVE - Static variable in class org.lsst.ccs.subsystem.refrig.CompMaq20Device
Constants.
SW_COOLANT_VALVE - Static variable in class org.lsst.ccs.subsystem.refrig.CompMaq20Device
Constants.
SW_ENABLE - Static variable in class org.lsst.ccs.subsystem.refrig.CompPlutoDevice
Constants.
SW_HEATER - Static variable in class org.lsst.ccs.subsystem.refrig.CompPlutoDevice
Constants.
SW_LIGHTS - Static variable in class org.lsst.ccs.subsystem.refrig.CompPlutoDevice
Constants.
SW_ORIFICE_VALVE - Static variable in class org.lsst.ccs.subsystem.refrig.CompMaq20Device
Constants.
SW_SURGE_HEATER - Static variable in class org.lsst.ccs.subsystem.refrig.CompMaq20Device
Constants.

T

TempControl - Class in org.lsst.ccs.subsystem.refrig
Implements a temperature controller for the refrigeration system.
TempControl() - Constructor for class org.lsst.ccs.subsystem.refrig.TempControl
 
ThermalMain - Class in org.lsst.ccs.subsystem.refrig
Implements the refrigeration thermal control subsystem.
ThermalMain() - Constructor for class org.lsst.ccs.subsystem.refrig.ThermalMain
 
timeout - Variable in class org.lsst.ccs.subsystem.refrig.PowerDevice
 
TYPE_CURRENT - Static variable in class org.lsst.ccs.subsystem.refrig.HeaterPsDevice
Constants.
TYPE_MAIN_CURR - Static variable in class org.lsst.ccs.subsystem.refrig.HeaterPsDevice
Constants.
TYPE_MAIN_POWER - Static variable in class org.lsst.ccs.subsystem.refrig.HeaterPsDevice
Constants.
TYPE_MAIN_STATUS - Static variable in class org.lsst.ccs.subsystem.refrig.HeaterPsDevice
Constants.
TYPE_MAIN_TEMP - Static variable in class org.lsst.ccs.subsystem.refrig.HeaterPsDevice
Constants.
TYPE_MAIN_VOLTS - Static variable in class org.lsst.ccs.subsystem.refrig.HeaterPsDevice
Constants.
TYPE_POWER - Static variable in class org.lsst.ccs.subsystem.refrig.HeaterPsDevice
Constants.
TYPE_TEMP - Static variable in class org.lsst.ccs.subsystem.refrig.HeaterPsDevice
Constants.
TYPE_TOTAL_POWER - Static variable in class org.lsst.ccs.subsystem.refrig.HeaterPsDevice
Constants.
TYPE_VOLTAGE - Static variable in class org.lsst.ccs.subsystem.refrig.HeaterPsDevice
Constants.

U

updateCompState(Compressor, int) - Method in class org.lsst.ccs.subsystem.refrig.RefrigMain
Updates the refrigeration state for one compressor.
updateState() - Method in class org.lsst.ccs.subsystem.refrig.Compressor
Updates the compressor state.

W

WUDevice - Class in org.lsst.ccs.subsystem.refrig
Handles a WattsUp power meter.
WUDevice() - Constructor for class org.lsst.ccs.subsystem.refrig.WUDevice
 
A B C D E G H I L M N O P R S T U W 
Skip navigation links

Copyright © 2019 LSST. All rights reserved.