- GAIN - Static variable in class org.lsst.ccs.subsystem.rafts.AspicControl
-
- GD - Static variable in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Constants.
- GD_P - Static variable in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Constants.
- getAdcName(int) - Static method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Gets the name of of a slow ADC.
- getAf1() - Method in class org.lsst.ccs.subsystem.rafts.AspicControl
-
- getBiasDacsPowerState(double[], List<String>) - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Checks whether Bias voltage values are ON, OFF, DELTA
- getCcdMask() - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Gets the mask of CCDs being used.
- getCCDsPowerState() - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
measure power state of ccds, user version
turns off CCDs on error
- getCcdType() - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Gets the CCD type.
- getChanged() - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Gets the changed variable value
- getChanged() - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Gets the changed variable value
- getClamp() - Method in class org.lsst.ccs.subsystem.rafts.AspicControl
-
- getClockDacsPowerState(double[], List<String>, double) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Checks that 6 clock Dacs are within tolerance of zero (eg.
- getCsGate() - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Gets the Current Source gate DAC value.
- getCsGate() - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
- getCsGateP() - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Gets the Current Source gate current.
- getDataSource() - Method in class org.lsst.ccs.subsystem.rafts.SequencerProc
-
Gets the data source.
- getErrorAddr() - Method in class org.lsst.ccs.subsystem.rafts.SequencerProc
-
Gets error address.
- getFunctionMap() - Method in class org.lsst.ccs.subsystem.rafts.SequencerProc
-
Gets the map of functions.
- getGain() - Method in class org.lsst.ccs.subsystem.rafts.AspicControl
-
- getGd() - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Gets the Guard Diode DAC value.
- getGdP() - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Gets the Guard Diode voltage.
- getGroupForChannel(Channel) - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
- getHdwType() - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Gets the hardware type.
- getHwCcdType() - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Gets the hardware CCD type.
- getHwVersion(Aspic) - Static method in class org.lsst.ccs.subsystem.rafts.AspicControl
-
Gets the hardware version.
- getHwVersion() - Method in class org.lsst.ccs.subsystem.rafts.AspicControl
-
Deprecated.
- getHwVersion(BoardDacs) - Static method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Gets the hardware version.
- getHwVersion() - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Deprecated.
- getHwVersion(BoardDacs) - Static method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Gets the hardware version.
- getHwVersion() - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Deprecated.
- getHwVersion() - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Gets the hardware version.
- getId() - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Gets the REB ID.
- getIfcName() - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Gets the network interface name.
- getImageRegisters() - Method in class org.lsst.ccs.subsystem.rafts.SequencerProc
-
Gets the array of image parameter registers to be read
- getImageRegisters(String[], boolean) - Method in class org.lsst.ccs.subsystem.rafts.SequencerProc
-
Gets the array of image parameter register addresses to be read
- getMainMap() - Method in class org.lsst.ccs.subsystem.rafts.SequencerProc
-
Gets the map of main programs.
- getMains() - Method in class org.lsst.ccs.subsystem.rafts.SequencerProc
-
Gets the list of main programs.
- getMaxDelta() - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Get config param maxDelta
- getMaxStep() - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Get config param maxStep
- getMinTol() - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Get config param minTol
- getMonitorTasks() - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
- getOd() - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Gets the Output Drain DAC value.
- getOdP() - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Gets the Output Drain voltage.
- getOg() - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Gets the Output Gate DAC value.
- getOgP() - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Gets the Output Gate voltage.
- getOgSh() - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Gets the Output Gate shift DAC value.
- getParameter(String) - Method in class org.lsst.ccs.subsystem.rafts.SequencerProc
-
Gets a parameter value.
- getPclkHigh() - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Gets the high parallel clock rail DAC value.
- getPclkHighP() - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Gets the high parallel clock rail voltage.
- getPclkHighSh() - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Gets the high parallel clock rail shift DAC value.
- getPclkLow() - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Gets the low parallel clock rail DAC value.
- getPclkLowP() - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Gets the low parallel clock rail voltage.
- getPclkLowSh() - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Gets the low parallel clock rail shift DAC value.
- getPointers() - Method in class org.lsst.ccs.subsystem.rafts.SequencerProc
-
Gets the map of pointer information.
- getRaftNumber() - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Gets the raft number.
- getRc() - Method in class org.lsst.ccs.subsystem.rafts.AspicControl
-
- getRd() - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Gets the Reset Drain DAC value.
- getRdP() - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Gets the Reset Drain voltage.
- getREBConfig() - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Gets the REB configuration data.
- getRebGeometry() - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
- getRebNumber() - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Gets the REB number.
- getRebStatus() - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Gets the REB status block.
- getRebType() - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Gets the REB type.
- getRegister(int, int) - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Gets the contents of REB registers.
- getRgHigh() - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Gets the high reset gate rail DAC value.
- getRgHighP() - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Gets the high reset gate rail voltage.
- getRgHighSh() - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Gets the high reset gate rail shift DAC value.
- getRgLow() - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Gets the low reset gate rail DAC value.
- getRgLowP() - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Gets the low reset gate rail voltage.
- getRgLowSh() - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Gets the low reset gate rail shift DAC value.
- getSclkHigh() - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Gets the high serial clock rail DAC value.
- getSclkHighP() - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Gets the high serial clock rail voltage.
- getSclkHighSh() - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Gets the high serial clock rail shift DAC value.
- getSclkLow() - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Gets the low serial clock rail DAC value.
- getSclkLowP() - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Gets the low serial clock rail voltage.
- getSclkLowSh() - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Gets the low serial clock rail shift DAC value.
- getSequencer() - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Gets the associated sequencer.
- getSerialNumber() - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Gets the serial number.
- getSubroutineMap() - Method in class org.lsst.ccs.subsystem.rafts.SequencerProc
-
Gets the map of subroutines.
- getTime() - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Gets the time base as Unix time.
- getTime(String) - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
- getTm() - Method in class org.lsst.ccs.subsystem.rafts.AspicControl
-
- getUnders() - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Gets the bit mask of DAC channels under threshold
- getUpdateCCDsPowerState() - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
- SCLK_HIGH - Static variable in class org.lsst.ccs.subsystem.rafts.DacControl
-
- SCLK_HIGH_P - Static variable in class org.lsst.ccs.subsystem.rafts.DacControl
-
- SCLK_HIGH_SH - Static variable in class org.lsst.ccs.subsystem.rafts.DacControl
-
- SCLK_LOW - Static variable in class org.lsst.ccs.subsystem.rafts.DacControl
-
- SCLK_LOW_P - Static variable in class org.lsst.ccs.subsystem.rafts.DacControl
-
- SCLK_LOW_SH - Static variable in class org.lsst.ccs.subsystem.rafts.DacControl
-
- sendStep() - Method in class org.lsst.ccs.subsystem.rafts.SequencerProc
-
Sends a sequencer step command.
- sendStop() - Method in class org.lsst.ccs.subsystem.rafts.SequencerProc
-
Sends a sequencer stop command.
- SequencerProc - Class in org.lsst.ccs.subsystem.rafts
-
Routines for accessing a REB sequencer.
- SequencerProc(BaseSet) - Constructor for class org.lsst.ccs.subsystem.rafts.SequencerProc
-
Constructor.
- setAf1(int) - Method in class org.lsst.ccs.subsystem.rafts.AspicControl
-
Sets/gets the af1 (force first-stage gain to 1) value.
- setAllAspic(String, int, boolean) - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
- setAllAspicGain(int) - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Transversal setting of all Gains for the Aspics of this reb.
- setAllAspicRc(int) - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Transversal setting of all Rcs for the Aspics of this reb.
- setAllAspicTM(boolean) - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Transversal setting of all TM for the Aspics of this reb.
- setBackBias(boolean) - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Turns back bias on or off.
- setBiasDacsCalibration(double[], List<String>, boolean) - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Measure and Set BiasDac Calibration to converge measured and configured
voltages
- setCCDClocksLow() - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Sets Sequencer Clock lines to low state
Corrupts the sequencer file -- needs strategy revision
Needed in [WG]REB power management but incomplete
- setCcdMask(int) - Method in class org.lsst.ccs.subsystem.rafts.SequencerProc
-
Sets the mask of CCDs being used.
- setCcdType(CCDType) - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Sets the CCD type.
- setClamp(int) - Method in class org.lsst.ccs.subsystem.rafts.AspicControl
-
Sets/gets the clamp mask.
- setClientFactory(ClientFactory) - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Sets the client factory.
- setClockDacsCalibration(double[], List<String>, boolean) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Measure and Set ClockDac offsets to converge measured and configured voltages
- setCsGate(int) - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Sets the Current Source gate DAC value.
- setCsGate(int[]) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets/Gets the current source gates.
- setCsGateP(double) - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Sets the Current Source gate current.
- setDataSource(int) - Method in class org.lsst.ccs.subsystem.rafts.SequencerProc
-
Sets the data source.
- setFitsConditions(String, double, double) - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Sets the FITS file test conditions.
- setGain(int) - Method in class org.lsst.ccs.subsystem.rafts.AspicControl
-
Sets/gets the gain.
- setGd(int) - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Sets the Guard Diode DAC value.
- setGdMax(double) - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Sets the Guard Diode voltage maximum.
- setGdMin(double) - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Sets the Guard Diode voltage minimum.
- setGdP(double) - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Sets the Guard Diode voltage.
- setHeater(int, double) - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Sets a heater voltage.
- setHeaterPower(int, double) - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Sets heater power.
- setIfcName(String) - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
- setOd(int) - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Sets the Output Drain DAC value.
- setOdMax(double) - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Sets the Output Drain voltage maximum.
- setOdMin(double) - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Sets the Output Drain voltage minimum.
- setOdP(double) - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Sets the Output Drain voltage.
- setOg(int) - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Sets the Output Gate DAC value.
- setOgMax(double) - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Sets the Output Gate voltage maximum.
- setOgMin(double) - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Sets the Output Gate voltage minimum.
- setOgP(double) - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Sets the Output Gate voltage.
- setOgSh(int) - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Sets the Output Gate shift DAC value.
- setOnline(boolean) - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
- setParameter(String, int) - Method in class org.lsst.ccs.subsystem.rafts.SequencerProc
-
Sets a parameter value.
- setParameterBulk(Map<String, Object>) - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Augments setting of parameters to trigger CCDsPowerState update
Parameters are set by ConfigurationChanger methods
If parameters match the pattern the rebDevice updateCCDsPowerState flag is set
If parameters match the pattern the matching bits in this.changed are set
- setParameterBulk(Map<String, Object>) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Augments setting of parameters to trigger CCDsPowerState update
Parameters are actually set by ConfigurationChanger methods
- setPclkHigh(int) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the high parallel clock rail DAC value.
- setPclkHighMax(double) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the high parallel clock rail voltage maximum.
- setPclkHighMin(double) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the high parallel clock rail voltage minimum.
- setPclkHighP(double) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the high parallel clock rail voltage.
- setPclkHighSh(int) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the high parallel clock rail shift DAC value.
- setPclkLow(int) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the low parallel clock rail DAC value.
- setPclkLowMax(double) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the low parallel clock rail voltage maximum.
- setPclkLowMin(double) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the low parallel clock rail voltage minimum.
- setPclkLowP(double) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the low parallel clock rail voltage.
- setPclkLowSh(int) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the low parallel clock rail shift DAC value.
- setRc(int) - Method in class org.lsst.ccs.subsystem.rafts.AspicControl
-
Sets/gets the rc value.
- setRd(int) - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Sets the Reset Drain DAC value.
- setRdMax(double) - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Sets the Reset Drain voltage maximum.
- setRdMin(double) - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Sets the Reset Drain voltage minimum.
- setRdP(double) - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Sets the Reset Drain voltage.
- setREBConfig(REB) - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Sets the REB configuration data.
- setRebGeometry(Reb) - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
- setRegister(int, int[]) - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Sets the contents of REB registers.
- setRgHigh(int) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the high reset gate rail DAC value.
- setRgHighMax(double) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the high reset gate rail voltage maximum.
- setRgHighMin(double) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the high reset gate rail voltage minimum.
- setRgHighP(double) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the high reset gate rail voltage.
- setRgHighSh(int) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the high reset gate rail shift DAC value.
- setRgLow(int) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the low reset gate rail DAC value.
- setRgLowMax(double) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the low reset gate rail voltage maximum.
- setRgLowMin(double) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the low reset gate rail voltage minimum.
- setRgLowP(double) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the low reset gate rail voltage.
- setRgLowSh(int) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the low reset gate rail shift DAC value.
- setScienceCCD(boolean) - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Sets whether a science CCD is being used on a WREB.
- setSclkHigh(int) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the high serial clock rail DAC value.
- setSclkHighMax(double) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the high serial clock rail voltage maximum.
- setSclkHighMin(double) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the high serial clock rail voltage minimum.
- setSclkHighP(double) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the high serial clock rail voltage.
- setSclkHighSh(int) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the high serial clock rail shift DAC value.
- setSclkLow(int) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the low serial clock rail DAC value.
- setSclkLowMax(double) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the low serial clock rail voltage maximum.
- setSclkLowMin(double) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the low serial clock rail voltage minimum.
- setSclkLowP(double) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the low serial clock rail voltage.
- setSclkLowSh(int) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the low serial clock rail shift DAC value.
- setStart(String) - Method in class org.lsst.ccs.subsystem.rafts.SequencerProc
-
Sets the sequencer start address.
- setStart(int) - Method in class org.lsst.ccs.subsystem.rafts.SequencerProc
-
Sets the sequencer start address.
- setTime() - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Sets the time base to the current system time.
- setTm(int) - Method in class org.lsst.ccs.subsystem.rafts.AspicControl
-
Sets/gets the tm (transparent mode) value.
- setUpdateCCDsPowerState() - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
- simulateDisconnection() - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Simulate a disconnect
- startSequencer() - Method in class org.lsst.ccs.subsystem.rafts.SequencerProc
-
Starts the sequencer.