- GD - Static variable in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Constants.
- GD_P - Static variable in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Constants.
- generateAlert(RaftAlert, AlertState) - Method in class org.lsst.ccs.subsystem.rafts.RaftsCommands
-
- getAdcName(int) - Static method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Gets the name of of a slow ADC.
- getAf1() - Method in class org.lsst.ccs.subsystem.rafts.AspicControl
-
- getBiasDacsPowerState(List<REBDevice.AdcData>, StringBuilder) - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Checks that Bias Dacs are within tolerance of zero (eg.
- getCcdMask() - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Gets the mask of CCDs being used.
- getCCDsPowerState() - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
check power state of ccds
return exception to caller if not safe to power on
- getCcdType() - Method in class org.lsst.ccs.subsystem.rafts.RaftsCommands
-
Gets the CCD type
- getCcdType() - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Gets the CCD type.
- getClamp() - Method in class org.lsst.ccs.subsystem.rafts.AspicControl
-
- getClockDacsPowerState(List<REBDevice.AdcData>, StringBuilder, double) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Checks that 6 clock Dacs are within tolerance of zero (eg.
- getControlTemp() - Method in class org.lsst.ccs.subsystem.rafts.RaftsCommands
-
Gets the control temperature
- getCsGate() - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Gets the Current Source gate DAC value.
- getCsGate() - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
- getCsGateP() - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Gets the Current Source gate current.
- getDataSource() - Method in class org.lsst.ccs.subsystem.rafts.RaftsCommands
-
Gets the data sources from all REBs.
- getDataSource() - Method in class org.lsst.ccs.subsystem.rafts.SequencerProc
-
Gets the data source.
- getErrorAddr() - Method in class org.lsst.ccs.subsystem.rafts.SequencerProc
-
Gets error address.
- getFitsService() - Method in class org.lsst.ccs.subsystem.rafts.ImageProc
-
Get the corresponding FitsService
- getFullState() - Method in class org.lsst.ccs.subsystem.rafts.RaftsMain
-
Gets the full state of the rafts module.
- getFunctionMap() - Method in class org.lsst.ccs.subsystem.rafts.RaftsCommands
-
Deprecated.
- getFunctionMap() - Method in class org.lsst.ccs.subsystem.rafts.SequencerProc
-
Gets the map of functions.
- getGain() - Method in class org.lsst.ccs.subsystem.rafts.AspicControl
-
- getGd() - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Gets the Guard Diode DAC value.
- getGdP() - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Gets the Guard Diode voltage.
- getHdwType() - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Gets the hardware type.
- getHwCcdType() - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Gets the hardware CCD type.
- getHwVersion(Aspic) - Static method in class org.lsst.ccs.subsystem.rafts.AspicControl
-
Gets the hardware version.
- getHwVersion() - Method in class org.lsst.ccs.subsystem.rafts.AspicControl
-
Deprecated.
- getHwVersion(BoardDacs) - Static method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Gets the hardware version.
- getHwVersion() - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Deprecated.
- getHwVersion(BoardDacs) - Static method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Gets the hardware version.
- getHwVersion() - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Deprecated.
- getHwVersion() - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Gets the hardware version.
- getId() - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Gets the REB ID.
- getIfcName() - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Gets the network interface name.
- getImage(int, int, int) - Method in class org.lsst.ccs.subsystem.rafts.ImageProc
-
Gets a portion of the current image.
- getImage(String, int, int) - Static method in class org.lsst.ccs.subsystem.rafts.RaftsMain
-
Gets a portion of a saved raw image.
- getImage(int, int) - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Gets a portion of the current image.
- getImage(int, int, int) - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Gets a portion of the current image.
- getImageMetadata() - Method in class org.lsst.ccs.subsystem.rafts.ImageProc
-
Gets the DAQ metadata for the current image.
- getImageMetadata() - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Gets the DAQ metadata for the current image.
- getImageProc() - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Gets the associated image processor.
- getImageRegisters() - Method in class org.lsst.ccs.subsystem.rafts.SequencerProc
-
Gets the array of image parameter registers to be read
- getImageRegisters(String[], boolean) - Method in class org.lsst.ccs.subsystem.rafts.SequencerProc
-
Gets the array of image parameter register addresses to be read
- getImageStats() - Method in class org.lsst.ccs.subsystem.rafts.ImageProc
-
Gets pixel value statistics for the current image.
- getMainMap() - Method in class org.lsst.ccs.subsystem.rafts.RaftsCommands
-
Deprecated.
- getMainMap() - Method in class org.lsst.ccs.subsystem.rafts.SequencerProc
-
Gets the map of main programs.
- getMains() - Method in class org.lsst.ccs.subsystem.rafts.SequencerProc
-
Gets the list of main programs.
- getOd() - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Gets the Output Drain DAC value.
- getOdP() - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Gets the Output Drain voltage.
- getOg() - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Gets the Output Gate DAC value.
- getOgP() - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Gets the Output Gate voltage.
- getOgSh() - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Gets the Output Gate shift DAC value.
- getParameter(String) - Method in class org.lsst.ccs.subsystem.rafts.RaftsCommands
-
Deprecated.
- getParameter(String) - Method in class org.lsst.ccs.subsystem.rafts.SequencerProc
-
Gets a parameter value.
- getPartition() - Method in class org.lsst.ccs.subsystem.rafts.GlobalProc
-
Gets the partition name.
- getPclkHigh() - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Gets the high parallel clock rail DAC value.
- getPclkHighP() - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Gets the high parallel clock rail voltage.
- getPclkHighSh() - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Gets the high parallel clock rail shift DAC value.
- getPclkLow() - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Gets the low parallel clock rail DAC value.
- getPclkLowP() - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Gets the low parallel clock rail voltage.
- getPclkLowSh() - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Gets the low parallel clock rail shift DAC value.
- getPointers() - Method in class org.lsst.ccs.subsystem.rafts.RaftsCommands
-
Deprecated.
- getPointers() - Method in class org.lsst.ccs.subsystem.rafts.SequencerProc
-
Gets the map of pointer information.
- getRaftNumber() - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Gets the raft number.
- getRc() - Method in class org.lsst.ccs.subsystem.rafts.AspicControl
-
- getRd() - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Gets the Reset Drain DAC value.
- getRdP() - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Gets the Reset Drain voltage.
- getREBConfig() - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Gets the REB configuration data.
- getREBDeviceNames() - Method in class org.lsst.ccs.subsystem.rafts.RaftsCommands
-
Gets the list of REB device names.
- getREBDevices() - Method in class org.lsst.ccs.subsystem.rafts.RaftsCommands
-
Deprecated.
- getRebGeometry() - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
- getREBHwVersions() - Method in class org.lsst.ccs.subsystem.rafts.RaftsCommands
-
Gets the list of REB hardware versions.
- getREBIds() - Method in class org.lsst.ccs.subsystem.rafts.RaftsCommands
-
Gets the list of REB IDs.
- getRebNumber() - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Gets the REB number.
- getREBSerialNumbers() - Method in class org.lsst.ccs.subsystem.rafts.RaftsCommands
-
Gets the list of REB serial numbers.
- getRebStatus() - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Gets the REB status block.
- getRebType() - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Gets the REB type.
- getRegister(int, int) - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Gets the contents of REB registers.
- getRgHigh() - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Gets the high reset gate rail DAC value.
- getRgHighP() - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Gets the high reset gate rail voltage.
- getRgHighSh() - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Gets the high reset gate rail shift DAC value.
- getRgLow() - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Gets the low reset gate rail DAC value.
- getRgLowP() - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Gets the low reset gate rail voltage.
- getRgLowSh() - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Gets the low reset gate rail shift DAC value.
- getSclkHigh() - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Gets the high serial clock rail DAC value.
- getSclkHighP() - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Gets the high serial clock rail voltage.
- getSclkHighSh() - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Gets the high serial clock rail shift DAC value.
- getSclkLow() - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Gets the low serial clock rail DAC value.
- getSclkLowP() - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Gets the low serial clock rail voltage.
- getSclkLowSh() - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Gets the low serial clock rail shift DAC value.
- getSequencer() - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Gets the associated sequencer.
- getSequencerFunctionMap() - Method in class org.lsst.ccs.subsystem.rafts.RaftsCommands
-
Gets the list of all function maps.
- getSequencerMainMap() - Method in class org.lsst.ccs.subsystem.rafts.RaftsCommands
-
Gets the list of all main program maps.
- getSequencerParameter(String) - Method in class org.lsst.ccs.subsystem.rafts.RaftsCommands
-
Gets the list of all values for a parameter.
- getSequencerPointers() - Method in class org.lsst.ccs.subsystem.rafts.RaftsCommands
-
Gets the list of all pointer information maps.
- getSequencerStart() - Method in class org.lsst.ccs.subsystem.rafts.RaftsCommands
-
Get the name of the Main routine that will be invoked when the sequencer
starts.
- getSequencerSubroutineMap() - Method in class org.lsst.ccs.subsystem.rafts.RaftsCommands
-
Gets the list of all subroutine maps.
- getSerialNumber() - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Gets the serial number.
- getSubroutineMap() - Method in class org.lsst.ccs.subsystem.rafts.RaftsCommands
-
Deprecated.
- getSubroutineMap() - Method in class org.lsst.ccs.subsystem.rafts.SequencerProc
-
Gets the map of subroutines.
- getTemperature() - Method in class org.lsst.ccs.subsystem.rafts.TempControl
-
Gets the target temperature.
- getTime() - Method in class org.lsst.ccs.subsystem.rafts.RaftsCommands
-
Gets all time base values.
- getTime() - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Gets the time base as Unix time.
- getTime(String) - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
- getTimes() - Method in class org.lsst.ccs.subsystem.rafts.RaftsCommands
-
Gets all time base values.
- getTm() - Method in class org.lsst.ccs.subsystem.rafts.AspicControl
-
- GlobalProc - Class in org.lsst.ccs.subsystem.rafts
-
Routines for accessing the whole raft
- GlobalProc() - Constructor for class org.lsst.ccs.subsystem.rafts.GlobalProc
-
- GlobalVisualizationClient - Class in org.lsst.ccs.subsystem.rafts
-
- GlobalVisualizationClient() - Constructor for class org.lsst.ccs.subsystem.rafts.GlobalVisualizationClient
-
- saveFitsImage(String, FitsHeaderMetadataProvider) - Method in class org.lsst.ccs.subsystem.rafts.ImageProc
-
Saves the current image data as one or more FITS files.
- saveFitsImage(String, FitsHeaderMetadataProvider, boolean) - Method in class org.lsst.ccs.subsystem.rafts.ImageProc
-
Saves the current image data as one or more FITS files.
- saveFitsImage(String) - Method in class org.lsst.ccs.subsystem.rafts.ImageProc
-
- saveFitsImage(String) - Method in class org.lsst.ccs.subsystem.rafts.RaftsCommands
-
Saves the current image data as one or more FITS files.
- saveFitsImage(String, FitsHeaderMetadataProvider) - Method in class org.lsst.ccs.subsystem.rafts.RaftsCommands
-
- saveImage(String) - Method in class org.lsst.ccs.subsystem.rafts.ImageProc
-
Saves the current image as raw bytes.
- saveImage(String) - Method in class org.lsst.ccs.subsystem.rafts.RaftsCommands
-
Saves the current image data as one or more sets of raw bytes.
- saveNamedConfig(String) - Method in class org.lsst.ccs.subsystem.rafts.RaftsMain
-
Saves a named rafts configuration.
- SCLK_HIGH - Static variable in class org.lsst.ccs.subsystem.rafts.DacControl
-
- SCLK_HIGH_P - Static variable in class org.lsst.ccs.subsystem.rafts.DacControl
-
- SCLK_HIGH_SH - Static variable in class org.lsst.ccs.subsystem.rafts.DacControl
-
- SCLK_LOW - Static variable in class org.lsst.ccs.subsystem.rafts.DacControl
-
- SCLK_LOW_P - Static variable in class org.lsst.ccs.subsystem.rafts.DacControl
-
- SCLK_LOW_SH - Static variable in class org.lsst.ccs.subsystem.rafts.DacControl
-
- sendImageData(ImageMetadata, ByteBuffer, CCD, ReadOutParameters) - Method in class org.lsst.ccs.subsystem.rafts.GlobalVisualizationClient
-
- sendStep() - Method in class org.lsst.ccs.subsystem.rafts.SequencerProc
-
Sends a sequencer step command.
- sendStop() - Method in class org.lsst.ccs.subsystem.rafts.SequencerProc
-
Sends a sequencer stop command.
- SequencerProc - Class in org.lsst.ccs.subsystem.rafts
-
Routines for accessing a REB sequencer.
- SequencerProc(BaseSet) - Constructor for class org.lsst.ccs.subsystem.rafts.SequencerProc
-
Constructor.
- setAf1(int) - Method in class org.lsst.ccs.subsystem.rafts.AspicControl
-
Sets/gets the af1 (force first-stage gain to 1) value.
- setAllAspicGain(int) - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Transversal setting of all Gains for the Aspics of this reb.
- setAllAspicRc(int) - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Transversal setting of all Rcs for the Aspics of this reb.
- setAllAspicTM(boolean) - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Transversal setting of all TM for the Aspics of this reb.
- setBackBias(boolean) - Method in class org.lsst.ccs.subsystem.rafts.RaftsCommands
-
Sets the back bias on states.
- setBackBias(boolean) - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Turns back bias on or off.
- setCCDClocksLow() - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Sets Sequencer Clock lines to low state
Corrupts the sequencer file -- needs strategy revision
Needed in [WG]REB power management but incomplete
- setCcdMask(int) - Method in class org.lsst.ccs.subsystem.rafts.ImageProc
-
Sets the mask of CCDs being used.
- setCcdMask(int) - Method in class org.lsst.ccs.subsystem.rafts.SequencerProc
-
Sets the mask of CCDs being used.
- setCcdType(CcdType) - Method in class org.lsst.ccs.subsystem.rafts.RaftsCommands
-
Sets the CCD type.
- setCcdType(String) - Method in class org.lsst.ccs.subsystem.rafts.RaftsCommands
-
Sets the CCD type.
- setCcdType(CcdType) - Method in class org.lsst.ccs.subsystem.rafts.RaftsMain
-
Sets the CCD type
- setCcdType(CcdType) - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Sets the CCD type.
- setClamp(int) - Method in class org.lsst.ccs.subsystem.rafts.AspicControl
-
Sets/gets the clamp mask.
- setClientFactory(ClientFactory) - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Sets the client factory.
- setControlTemp(double) - Method in class org.lsst.ccs.subsystem.rafts.RaftsCommands
-
Sets the control temperature
- setCsGate(int) - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Sets the Current Source gate DAC value.
- setCsGate(int[]) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets/Gets the current source gates.
- setCsGateP(double) - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Sets the Current Source gate current.
- setDataInversion(boolean) - Method in class org.lsst.ccs.subsystem.rafts.ImageProc
-
Sets whether image data values are inverted
- setDataSource(int) - Method in class org.lsst.ccs.subsystem.rafts.RaftsCommands
-
Sets the data sources in all REBs.
- setDataSource(int) - Method in class org.lsst.ccs.subsystem.rafts.SequencerProc
-
Sets the data source.
- setDefaultImageDirectory(String) - Method in class org.lsst.ccs.subsystem.rafts.ImageProc
-
Sets the default image directory.
- setDefaultImageDirectory(String) - Method in class org.lsst.ccs.subsystem.rafts.RaftsCommands
-
Sets the default image directory.
- setExposureTime(double) - Method in class org.lsst.ccs.subsystem.rafts.RaftsCommands
-
Sets the FITS image exposure time.
- setFitsConditions(String, double, double) - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Sets the FITS file test conditions.
- setFitsFileNamePattern(String) - Method in class org.lsst.ccs.subsystem.rafts.ImageProc
-
Sets the FITS image file name pattern.
- setFitsFileNamePattern(String) - Method in class org.lsst.ccs.subsystem.rafts.RaftsCommands
-
Sets the FITS image file name pattern.
- setGain(int) - Method in class org.lsst.ccs.subsystem.rafts.AspicControl
-
Sets/gets the gain.
- setGd(int) - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Sets the Guard Diode DAC value.
- setGdMax(double) - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Sets the Guard Diode voltage maximum.
- setGdMin(double) - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Sets the Guard Diode voltage minimum.
- setGdP(double) - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Sets the Guard Diode voltage.
- setHeaderKeyword(String, String, Serializable) - Method in class org.lsst.ccs.subsystem.rafts.RaftsCommands
-
Set the value of a named HDU Header Keyword
- setHeaderKeyword(String, String, Serializable, boolean) - Method in class org.lsst.ccs.subsystem.rafts.RaftsCommands
-
Set the value of a header keyword for a given named HDU.
- setHeaderKeyword(String, Map<String, Serializable>) - Method in class org.lsst.ccs.subsystem.rafts.RaftsCommands
-
Set the values of a named HDU Header Keywords
- setHeaderKeywordForCCD(String, String, Serializable, boolean) - Method in class org.lsst.ccs.subsystem.rafts.RaftsCommands
-
Set the value of a header keyword for a given named HDU.
- setHeater(int, double) - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Sets a heater voltage.
- setHeaterPower(int, double) - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Sets heater power.
- setImageDataFileNamePattern(String) - Method in class org.lsst.ccs.subsystem.rafts.ImageProc
-
Sets the raw image data file name pattern.
- setImageDataFileNamePattern(String) - Method in class org.lsst.ccs.subsystem.rafts.RaftsCommands
-
Sets the raw image data file name pattern.
- setImageDataInversion(boolean) - Method in class org.lsst.ccs.subsystem.rafts.RaftsCommands
-
Sets whether image data values are inverted
- setNumRebCcds(int) - Method in class org.lsst.ccs.subsystem.rafts.ImageProc
-
Sets the number of CCDs on the REB.
- setOd(int) - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Sets the Output Drain DAC value.
- setOdMax(double) - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Sets the Output Drain voltage maximum.
- setOdMin(double) - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Sets the Output Drain voltage minimum.
- setOdP(double) - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Sets the Output Drain voltage.
- setOg(int) - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Sets the Output Gate DAC value.
- setOgMax(double) - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Sets the Output Gate voltage maximum.
- setOgMin(double) - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Sets the Output Gate voltage minimum.
- setOgP(double) - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Sets the Output Gate voltage.
- setOgSh(int) - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Sets the Output Gate shift DAC value.
- setOnline(boolean) - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
- setParameter(String, int) - Method in class org.lsst.ccs.subsystem.rafts.RaftsCommands
-
Deprecated.
- setParameter(String, int) - Method in class org.lsst.ccs.subsystem.rafts.SequencerProc
-
Sets a parameter value.
- setPatternProperty(String, String) - Method in class org.lsst.ccs.subsystem.rafts.ImageProc
-
Set a property for resolving file name and output directory
- setPatternProperty(String, String) - Method in class org.lsst.ccs.subsystem.rafts.RaftsCommands
-
Set a pattern property for resolving file name and output directory.
- setPclkHigh(int) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the high parallel clock rail DAC value.
- setPclkHighMax(double) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the high parallel clock rail voltage maximum.
- setPclkHighMin(double) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the high parallel clock rail voltage minimum.
- setPclkHighP(double) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the high parallel clock rail voltage.
- setPclkHighSh(int) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the high parallel clock rail shift DAC value.
- setPclkLow(int) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the low parallel clock rail DAC value.
- setPclkLowMax(double) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the low parallel clock rail voltage maximum.
- setPclkLowMin(double) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the low parallel clock rail voltage minimum.
- setPclkLowP(double) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the low parallel clock rail voltage.
- setPclkLowSh(int) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the low parallel clock rail shift DAC value.
- setPrimaryHeaderKeyword(String, Serializable) - Method in class org.lsst.ccs.subsystem.rafts.RaftsCommands
-
Set the value of Primary Header Keyword
- setPrimaryHeaderKeyword(Map<String, Serializable>) - Method in class org.lsst.ccs.subsystem.rafts.RaftsCommands
-
Set the values of Primary Header Keywords
- setRc(int) - Method in class org.lsst.ccs.subsystem.rafts.AspicControl
-
Sets/gets the rc value.
- setRd(int) - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Sets the Reset Drain DAC value.
- setRdMax(double) - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Sets the Reset Drain voltage maximum.
- setRdMin(double) - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Sets the Reset Drain voltage minimum.
- setRdP(double) - Method in class org.lsst.ccs.subsystem.rafts.BiasControl
-
Sets the Reset Drain voltage.
- setREBConfig(REB) - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Sets the REB configuration data.
- setRebGeometry(Reb) - Method in class org.lsst.ccs.subsystem.rafts.ImageProc
-
Set the Reb Geometry corresponding to this ImageProc instance.
- setRebGeometry(Reb) - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
- setRegister(int, int[]) - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Sets the contents of REB registers.
- setRegisters(int, int[]) - Method in class org.lsst.ccs.subsystem.rafts.GlobalProc
-
Sets the registers to be read during image acquisition.
- setRgHigh(int) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the high reset gate rail DAC value.
- setRgHighMax(double) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the high reset gate rail voltage maximum.
- setRgHighMin(double) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the high reset gate rail voltage minimum.
- setRgHighP(double) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the high reset gate rail voltage.
- setRgHighSh(int) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the high reset gate rail shift DAC value.
- setRgLow(int) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the low reset gate rail DAC value.
- setRgLowMax(double) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the low reset gate rail voltage maximum.
- setRgLowMin(double) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the low reset gate rail voltage minimum.
- setRgLowP(double) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the low reset gate rail voltage.
- setRgLowSh(int) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the low reset gate rail shift DAC value.
- setScienceCCD(boolean) - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Sets whether a science CCD is being used on a WREB.
- setSclkHigh(int) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the high serial clock rail DAC value.
- setSclkHighMax(double) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the high serial clock rail voltage maximum.
- setSclkHighMin(double) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the high serial clock rail voltage minimum.
- setSclkHighP(double) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the high serial clock rail voltage.
- setSclkHighSh(int) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the high serial clock rail shift DAC value.
- setSclkLow(int) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the low serial clock rail DAC value.
- setSclkLowMax(double) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the low serial clock rail voltage maximum.
- setSclkLowMin(double) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the low serial clock rail voltage minimum.
- setSclkLowP(double) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the low serial clock rail voltage.
- setSclkLowSh(int) - Method in class org.lsst.ccs.subsystem.rafts.DacControl
-
Sets the low serial clock rail shift DAC value.
- setSequenceNumber(int) - Method in class org.lsst.ccs.subsystem.rafts.RaftsCommands
-
Set an external sequence number.
- setSequencerParameter(String, int) - Method in class org.lsst.ccs.subsystem.rafts.RaftsCommands
-
Sets a sequencer parameter value in all REBs.
- setSequencerStart(String) - Method in class org.lsst.ccs.subsystem.rafts.RaftsCommands
-
Sets the start address for all sequencers.
- setStart(String) - Method in class org.lsst.ccs.subsystem.rafts.RaftsCommands
-
Deprecated.
- setStart(String) - Method in class org.lsst.ccs.subsystem.rafts.SequencerProc
-
Sets the sequencer start address.
- setStart(int) - Method in class org.lsst.ccs.subsystem.rafts.SequencerProc
-
Sets the sequencer start address.
- setTemperature(double) - Method in class org.lsst.ccs.subsystem.rafts.TempControl
-
Sets the target temperature.
- setTime() - Method in class org.lsst.ccs.subsystem.rafts.RaftsCommands
-
Sets the time base to the current system time.
- setTime() - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Sets the time base to the current system time.
- setTm(int) - Method in class org.lsst.ccs.subsystem.rafts.AspicControl
-
Sets/gets the tm (transparent mode) value.
- setUpdatePeriod(int) - Method in class org.lsst.ccs.subsystem.rafts.RaftsMain
-
Sets the update period.
- shutdown() - Method in class org.lsst.ccs.subsystem.rafts.GlobalVisualizationClient
-
- simulateDisconnection() - Method in class org.lsst.ccs.subsystem.rafts.REBDevice
-
Simulate a disconnect
- splitImage() - Method in class org.lsst.ccs.subsystem.rafts.ImageProc
-
Splits the current image into its segments.
- startLoop(double) - Method in class org.lsst.ccs.subsystem.rafts.TempControl
-
Starts the control loop.
- startLoop() - Method in class org.lsst.ccs.subsystem.rafts.TempControl
-
Starts the control loop.
- startSequencer() - Method in class org.lsst.ccs.subsystem.rafts.GlobalProc
-
Starts sequencer (no image data).
- startSequencer(int) - Method in class org.lsst.ccs.subsystem.rafts.GlobalProc
-
Starts sequencer (no image data).
- startSequencer() - Method in class org.lsst.ccs.subsystem.rafts.RaftsCommands
-
Starts the sequencers.
- startSequencer() - Method in class org.lsst.ccs.subsystem.rafts.SequencerProc
-
Starts the sequencer.
- startTempControl() - Method in class org.lsst.ccs.subsystem.rafts.RaftsCommands
-
Starts temperature control
- stepSequencer() - Method in class org.lsst.ccs.subsystem.rafts.RaftsCommands
-
Sends a sequencer step command.
- stopLoop() - Method in class org.lsst.ccs.subsystem.rafts.TempControl
-
Stops the control loop.
- stopSequencer() - Method in class org.lsst.ccs.subsystem.rafts.RaftsCommands
-
Sends a sequencer stop command.
- stopTempControl() - Method in class org.lsst.ccs.subsystem.rafts.RaftsCommands
-
Stops temperature control