Skip navigation links
A B C D E F G H I K L M N O P Q R S T V W 

A

addControl(PowerControl) - Method in class org.lsst.ccs.subsystem.power.PowerGroup
Add a control channel to the group.
agent - Variable in class org.lsst.ccs.subsystem.power.RebPowerSupplyNode
 
agentStateService - Variable in class org.lsst.ccs.subsystem.power.RebPowerSupplyNode
 
ATSPowerMain - Class in org.lsst.ccs.subsystem.power
Implements the Auxiliary Telescope power control subsystem.
ATSPowerMain() - Constructor for class org.lsst.ccs.subsystem.power.ATSPowerMain
 
auxOff() - Method in class org.lsst.ccs.subsystem.power.ATSPowerMain
Turns off the auxiliary power.
auxOn() - Method in class org.lsst.ccs.subsystem.power.ATSPowerMain
Turns on the auxiliary power.

B

BfrComCamDevice - Class in org.lsst.ccs.subsystem.power
Interface to the SLAC BFR.
BfrComCamDevice() - Constructor for class org.lsst.ccs.subsystem.power.BfrComCamDevice
 
BfrDevice - Class in org.lsst.ccs.subsystem.power
Interface to the SLAC BFR.
BfrDevice() - Constructor for class org.lsst.ccs.subsystem.power.BfrDevice
 
BK1696Device - Class in org.lsst.ccs.subsystem.power
Interface to a B&K model 1696 power supply device.
BK1696Device() - Constructor for class org.lsst.ccs.subsystem.power.BK1696Device
Constructor
BK9130Device - Class in org.lsst.ccs.subsystem.power
Interface to a B&K model 9130 power supply device.
BK9130Device() - Constructor for class org.lsst.ccs.subsystem.power.BK9130Device
Constructor.
BK9130GroupDevice - Class in org.lsst.ccs.subsystem.power
Interface to a B&K model 9130 power supply device.
BK9130GroupDevice() - Constructor for class org.lsst.ccs.subsystem.power.BK9130GroupDevice
Constructor.
BKXLNDevice - Class in org.lsst.ccs.subsystem.power
Interface to a B&K XLN series power supply device.
BKXLNDevice() - Constructor for class org.lsst.ccs.subsystem.power.BKXLNDevice
Constructor
BROADCAST_TASK - Static variable in class org.lsst.ccs.subsystem.power.MainPower
 
build() - Method in class org.lsst.ccs.subsystem.power.ATSPowerMain
Power subsystem initialization
build() - Method in class org.lsst.ccs.subsystem.power.BulkPSEmergencyResponseManager
 
build() - Method in class org.lsst.ccs.subsystem.power.CornerRaftRebPowerSupplyNode
 
build() - Method in class org.lsst.ccs.subsystem.power.MainPower
Power subsystem initialization
build() - Method in class org.lsst.ccs.subsystem.power.QuadBox
Build phase
build() - Method in class org.lsst.ccs.subsystem.power.RebPower
Override build method of HasLifecycle.
build() - Method in class org.lsst.ccs.subsystem.power.RebPowerAlarm
 
build() - Method in class org.lsst.ccs.subsystem.power.RebPowerSupplyMain
 
build() - Method in class org.lsst.ccs.subsystem.power.RebPowerSupplyNode
 
build() - Method in class org.lsst.ccs.subsystem.power.RebPsBoardAlarm
 
build() - Method in class org.lsst.ccs.subsystem.power.RebPsDevice
 
BulkPSEmergencyResponseManager - Class in org.lsst.ccs.subsystem.power
This class manages the emergency response actions based on Alert payloads.
BulkPSEmergencyResponseManager() - Constructor for class org.lsst.ccs.subsystem.power.BulkPSEmergencyResponseManager
 

C

changeVoltage(double) - Method in class org.lsst.ccs.subsystem.power.PowerControl
Changes the voltage.
changeVoltage(double) - Method in class org.lsst.ccs.subsystem.power.PowerControlOld
Changes the voltage.
channel - Variable in class org.lsst.ccs.subsystem.power.RebPowerSupplyNode
 
checkChannel(Channel) - Method in class org.lsst.ccs.subsystem.power.BfrComCamDevice
Checks a monitoring channel's parameters for validity.
checkChannel(Channel) - Method in class org.lsst.ccs.subsystem.power.BfrDevice
Checks a monitoring channel's parameters for validity.
checkChannel(Channel) - Method in class org.lsst.ccs.subsystem.power.CpfeDevice
Checks a channel's parameters for validity.
checkChannel(Channel) - Method in class org.lsst.ccs.subsystem.power.EpduG3Device
Checks a monitoring channel's parameters for validity.
checkChannel(Channel) - Method in class org.lsst.ccs.subsystem.power.PduCommonDevice
Checks a monitoring channel's parameters for validity.
checkChannel(Channel) - Method in class org.lsst.ccs.subsystem.power.PduHvDevice
Checks a monitoring channel's parameters for validity.
checkChannel(Channel) - Method in class org.lsst.ccs.subsystem.power.PowerDevice
Checks a monitoring channel's parameters for validity.
checkChannel(Channel) - Method in class org.lsst.ccs.subsystem.power.RebBulkPsDevice
Checks a monitoring channel's parameters for validity.
checkChannel(Channel) - Method in class org.lsst.ccs.subsystem.power.RebPsDevice
 
checkChannel(Channel) - Method in class org.lsst.ccs.subsystem.power.RebPsDeviceOld
Checks a monitoring channel's parameters for validity.
checkPsTripped() - Method in class org.lsst.ccs.subsystem.power.RebPsDevice
Checks whether a power supply has tripped.
checkPsTripped() - Method in class org.lsst.ccs.subsystem.power.RebPsDeviceOld
Checks whether a power supply has tripped.
clearListener() - Method in class org.lsst.ccs.subsystem.power.RebPsDevice
Clears the event listener.
clearListener() - Method in class org.lsst.ccs.subsystem.power.RebPsDeviceOld
Clears the event listener.
close() - Method in class org.lsst.ccs.subsystem.power.BfrComCamDevice
Closes the connection.
close() - Method in class org.lsst.ccs.subsystem.power.BfrDevice
Closes the connection.
close() - Method in class org.lsst.ccs.subsystem.power.EpduG3Device
Closes the connection.
close() - Method in class org.lsst.ccs.subsystem.power.PduCommonDevice
Closes the connection.
close() - Method in class org.lsst.ccs.subsystem.power.PowerDevice
Closes the connection.
close() - Method in class org.lsst.ccs.subsystem.power.RebBulkPsDevice
Closes the connection.
close() - Method in class org.lsst.ccs.subsystem.power.RebPsDevice
 
close() - Method in class org.lsst.ccs.subsystem.power.RebPsDeviceOld
Closes the connection.
closed() - Method in class org.lsst.ccs.subsystem.power.RebPower
Called when a power supply device is closed.
closed() - Method in interface org.lsst.ccs.subsystem.power.RebPsDevice.Event
 
closed() - Method in interface org.lsst.ccs.subsystem.power.RebPsDeviceOld.Event
 
ComCamPdu24vcDevice - Class in org.lsst.ccs.subsystem.power
Interface to a SLAC 24V clean PDU.
ComCamPdu24vcDevice() - Constructor for class org.lsst.ccs.subsystem.power.ComCamPdu24vcDevice
 
ComCamPdu24vdDevice - Class in org.lsst.ccs.subsystem.power
Interface to a SLAC 24V dirty PDU.
ComCamPdu24vdDevice() - Constructor for class org.lsst.ccs.subsystem.power.ComCamPdu24vdDevice
 
ComCamPdu48vDevice - Class in org.lsst.ccs.subsystem.power
Interface to a SLAC 48V (dirty) PDU.
ComCamPdu48vDevice() - Constructor for class org.lsst.ccs.subsystem.power.ComCamPdu48vDevice
 
ComCamQuadBox - Class in org.lsst.ccs.subsystem.power
Implements the Quad Box control subsystem.
ComCamQuadBox() - Constructor for class org.lsst.ccs.subsystem.power.ComCamQuadBox
Constructor.
configure(Monitor, Device) - Method in class org.lsst.ccs.subsystem.power.PowerControlOld
Configures channel description.
configure(Monitor, Device) - Method in class org.lsst.ccs.subsystem.power.RebPsControl
Configures channel description.
CONN_TYPE_NOT_CONFIG - Static variable in class org.lsst.ccs.subsystem.power.PowerDevice
 
connected(AgentInfo...) - Method in class org.lsst.ccs.subsystem.power.ComCamQuadBox
 
connType - Variable in class org.lsst.ccs.subsystem.power.PowerDevice
 
CornerRaftRebPowerSupplyNode - Class in org.lsst.ccs.subsystem.power
A class representing an individual Reb for a Corner Rat.
CornerRaftRebPowerSupplyNode(PowerSupplyConfiguration, int) - Constructor for class org.lsst.ccs.subsystem.power.CornerRaftRebPowerSupplyNode
 
CpfeDevice - Class in org.lsst.ccs.subsystem.power
Handles a Lambda CPFE1000 power supply system.
CpfeDevice() - Constructor for class org.lsst.ccs.subsystem.power.CpfeDevice
Constructor

D

DEVC_ID_NOT_CONFIG - Static variable in class org.lsst.ccs.subsystem.power.PowerDevice
 
DEVC_PARM_NOT_CONFIG - Static variable in class org.lsst.ccs.subsystem.power.PowerDevice
 
devcId - Variable in class org.lsst.ccs.subsystem.power.PowerDevice
Data fields.
devcParm - Variable in class org.lsst.ccs.subsystem.power.PowerDevice
 
disconnected(AgentInfo...) - Method in class org.lsst.ccs.subsystem.power.ComCamQuadBox
Listens for the departure of the companion refrigeration subsystem.
dphiOff() - Method in class org.lsst.ccs.subsystem.power.ATSPowerMain
Turns off the DPHI voltage.
dphiOff() - Method in class org.lsst.ccs.subsystem.power.CornerRaftRebPowerSupplyNode
 
dphiOn() - Method in class org.lsst.ccs.subsystem.power.ATSPowerMain
Turns on the DPHI voltage.
dphiOn() - Method in class org.lsst.ccs.subsystem.power.CornerRaftRebPowerSupplyNode
 
dumpInfo() - Method in class org.lsst.ccs.subsystem.power.RebPsDevice
 

E

EatonPdus - Class in org.lsst.ccs.subsystem.power
Implements the Eaton PDU monitoring subsystem.
EatonPdus() - Constructor for class org.lsst.ccs.subsystem.power.EatonPdus
Constructor.
EmergencyResponseManager - Class in org.lsst.ccs.subsystem.power
This class manages the emergency response actions based on Alert payloads.
EmergencyResponseManager() - Constructor for class org.lsst.ccs.subsystem.power.EmergencyResponseManager
 
EpduG3Device - Class in org.lsst.ccs.subsystem.power
Interface to an Eaton PDU.
EpduG3Device() - Constructor for class org.lsst.ccs.subsystem.power.EpduG3Device
 

F

fanOff() - Method in class org.lsst.ccs.subsystem.power.ATSPowerMain
Turns off the fan power.
fanOn() - Method in class org.lsst.ccs.subsystem.power.ATSPowerMain
Turns on the fan power.
finalizeDictionary() - Method in class org.lsst.ccs.subsystem.power.RebPowerSupplyMain
 

G

getAlert(AlertState, AlertState) - Method in class org.lsst.ccs.subsystem.power.RebPowerAlarm
 
getAlert(AlertState, AlertState) - Method in class org.lsst.ccs.subsystem.power.RebPsBoardAlarm
 
getBulkPsSwitchName() - Method in class org.lsst.ccs.subsystem.power.RebPsDevice
Get the name of the switch name controlling this PS board.
getChanExtrema(int, RebPsDeviceOld.PsName, RebPsDeviceOld.ChanName) - Method in class org.lsst.ccs.subsystem.power.RebPower
Reads the maximum and minimum values of a channel.
getChanExtrema(RebPsDevice.PsName, RebPsDevice.ChanName) - Method in class org.lsst.ccs.subsystem.power.RebPowerSupplyNode
Reads the maximum and minimum values of a channel.
getConnType() - Method in class org.lsst.ccs.subsystem.power.PowerDevice
Gets the connection type.
getCurrent() - Method in class org.lsst.ccs.subsystem.power.PowerControl
Gets the current.
getCurrent() - Method in class org.lsst.ccs.subsystem.power.PowerControlOld
 
getDacs(boolean) - Method in class org.lsst.ccs.subsystem.power.RebPsDevice
Gets a set of DPHI or HV bias DAC values.
getDacs(boolean) - Method in class org.lsst.ccs.subsystem.power.RebPsDeviceOld
Gets a set of DPHI or HV bias DAC values.
getDevcId() - Method in class org.lsst.ccs.subsystem.power.PowerDevice
Gets the device ID.
getDevcParm() - Method in class org.lsst.ccs.subsystem.power.PowerDevice
Gets the device parameter.
getDevice() - Method in class org.lsst.ccs.subsystem.power.PowerControl
Gets the associated device
getErrors() - Method in class org.lsst.ccs.subsystem.power.RebPower
Gets the power supply error counters.
getErrors() - Method in class org.lsst.ccs.subsystem.power.RebPsDevice
Gets the error counters.
getErrors() - Method in class org.lsst.ccs.subsystem.power.RebPsDeviceOld
Gets the error counters.
getFullState() - Method in class org.lsst.ccs.subsystem.power.ATSPowerMain
Gets the full power state.
getFullState() - Method in class org.lsst.ccs.subsystem.power.ComCamQuadBox
Gets the full quad box state.
getFullState() - Method in class org.lsst.ccs.subsystem.power.MainPower
Gets the full power state.
getFullState() - Method in class org.lsst.ccs.subsystem.power.PathFinderQuadBox
Gets the full quad box state.
getFullState() - Method in class org.lsst.ccs.subsystem.power.QuadBox
Gets the full quad box state.
getFullState() - Method in class org.lsst.ccs.subsystem.power.RebPower
Gets the full REB power supply state.
getGroupForChannel(Channel) - Method in class org.lsst.ccs.subsystem.power.BfrComCamDevice
Gets the group for a channel.
getGroupForChannel(Channel) - Method in class org.lsst.ccs.subsystem.power.BfrDevice
Gets the group for a channel.
getHwChan() - Method in class org.lsst.ccs.subsystem.power.PowerControl
Gets the hardware channel.
getMaxChannel() - Method in class org.lsst.ccs.subsystem.power.PowerDevice
Gets the maximum channel number.
getMinChannel() - Method in class org.lsst.ccs.subsystem.power.PowerDevice
Gets the minimum channel number.
getName() - Method in class org.lsst.ccs.subsystem.power.PowerSupplyConfiguration
 
getOffDelay() - Method in class org.lsst.ccs.subsystem.power.PowerControl
Gets the power-off delay.
getOffDelay() - Method in class org.lsst.ccs.subsystem.power.PowerControlOld
 
getOnDelay() - Method in class org.lsst.ccs.subsystem.power.PowerControl
Gets the power-on delay.
getOnDelay() - Method in class org.lsst.ccs.subsystem.power.PowerControlOld
 
getPowerConfig() - Method in class org.lsst.ccs.subsystem.power.MainPower
Gets the configuration data.
getPowerConfig() - Method in class org.lsst.ccs.subsystem.power.PowerDeviceGroup
Gets the configuration data.
getPowerDriver() - Method in class org.lsst.ccs.subsystem.power.PowerDevice
Gets the power supply driver.
getPowerState() - Method in class org.lsst.ccs.subsystem.power.MainPower
Gets the power state.
getPowerState() - Method in class org.lsst.ccs.subsystem.power.PowerDeviceGroup
Gets the list of power state data.
getPowerState() - Method in class org.lsst.ccs.subsystem.power.PowerGroup
Gets the list of power state data.
getPowerSupplyChannelForReb(String) - Method in class org.lsst.ccs.subsystem.power.RebPowerSupplyWiring
 
getPowerSupplyChannelForRebHeater(String) - Method in class org.lsst.ccs.subsystem.power.RebPowerSupplyWiring
 
getPowerSupplyConfigurationForReb(String) - Method in class org.lsst.ccs.subsystem.power.RebPowerSupplyWiring
 
getPs() - Method in class org.lsst.ccs.subsystem.power.RebPsDevice
Gets the power supply driver.
getPs() - Method in class org.lsst.ccs.subsystem.power.RebPsDeviceOld
Gets the power supply driver.
getPsId() - Method in class org.lsst.ccs.subsystem.power.RebPsDevice
Gets the power supply ID.
getPsId() - Method in class org.lsst.ccs.subsystem.power.RebPsDeviceOld
Gets the power supply ID.
getPsTrippedStatus() - Method in class org.lsst.ccs.subsystem.power.RebPsDeviceOld
Checks whether a power supply has tripped.
getPsType() - Method in class org.lsst.ccs.subsystem.power.RebPsDevice
Gets the power supply type.
getPsType() - Method in class org.lsst.ccs.subsystem.power.RebPsDeviceOld
Gets the power supply type.
getPsVersion() - Method in class org.lsst.ccs.subsystem.power.RebPsDevice
Gets the power supply version.
getPsVersion() - Method in class org.lsst.ccs.subsystem.power.RebPsDeviceOld
Gets the power supply version.
getRebPowerAlert(RebPowerAlertType, String) - Static method in class org.lsst.ccs.subsystem.power.RebPowerAlarm
Utility method to create an Alert of a given type and for the given Reb
getRebPowerSuppyConfigurations() - Method in class org.lsst.ccs.subsystem.power.RebPowerSupplyWiring
 
getRebPsDeviceState() - Method in class org.lsst.ccs.subsystem.power.RebPsDevice
 
getRebs() - Method in class org.lsst.ccs.subsystem.power.PowerSupplyConfiguration
 
getRebsList() - Method in class org.lsst.ccs.subsystem.power.RebPowerSupplyWiring
 
getState() - Method in class org.lsst.ccs.subsystem.power.RebPsDeviceOld
Gets the power state data.
getSwitchDevice() - Method in class org.lsst.ccs.subsystem.power.BfrComCamDevice
Gets the switch device type.
getSwitchDevice() - Method in class org.lsst.ccs.subsystem.power.BfrDevice
Gets the switch device type.
getSwitchDevice() - Method in class org.lsst.ccs.subsystem.power.PduCommonDevice
Gets the switch device type
getSwitchDevice() - Method in class org.lsst.ccs.subsystem.power.QbMaq20Device
Gets the switch device type.
getSwitchDevice() - Method in class org.lsst.ccs.subsystem.power.RebBulkPsDevice
Gets the switch device type
getSwitchDevice() - Method in interface org.lsst.ccs.subsystem.power.SwitchControl
 
getSwitchNames() - Method in class org.lsst.ccs.subsystem.power.ComCamQuadBox
Gets the list of switch names.
getSwitchNames() - Method in class org.lsst.ccs.subsystem.power.PathFinderQuadBox
Gets the list of switch names.
getSwitchNames() - Method in class org.lsst.ccs.subsystem.power.QuadBox
Gets the list of switch names.
getVoltage() - Method in class org.lsst.ccs.subsystem.power.PowerControl
Gets the voltage.
getVoltage() - Method in class org.lsst.ccs.subsystem.power.PowerControlOld
 

H

HamegDevice - Class in org.lsst.ccs.subsystem.power
Interface to a Hameg HMP series power supply device.
HamegDevice() - Constructor for class org.lsst.ccs.subsystem.power.HamegDevice
Constructor.
handleException(DriverException) - Method in class org.lsst.ccs.subsystem.power.PowerDevice
Handle driver exceptions.
hasAlert(int) - Method in class org.lsst.ccs.subsystem.power.PduCommonDevice
Gets the alert state of a PDU channel.
hasAlert(int) - Method in interface org.lsst.ccs.subsystem.power.SwitchControl
 
hvBias - Variable in class org.lsst.ccs.subsystem.power.RebPowerSupplyNode
 
hvBiasOff() - Method in class org.lsst.ccs.subsystem.power.ATSPowerMain
Turns off the HV bias.
hvBiasOff() - Method in class org.lsst.ccs.subsystem.power.RebPowerSupplyNode
 
hvBiasOn() - Method in class org.lsst.ccs.subsystem.power.ATSPowerMain
Turns on the HV bias.
hvBiasOn() - Method in class org.lsst.ccs.subsystem.power.RebPowerSupplyNode
 

I

init() - Method in class org.lsst.ccs.subsystem.power.BulkPSEmergencyResponseManager
 
init() - Method in class org.lsst.ccs.subsystem.power.EmergencyResponseManager
 
init() - Method in class org.lsst.ccs.subsystem.power.PowerControl
Life-cycle initialization.
init() - Method in class org.lsst.ccs.subsystem.power.QuadBox
Registers the possible alerts.
init() - Method in class org.lsst.ccs.subsystem.power.RebPower
Override init method of HasLifecycle.
init() - Method in class org.lsst.ccs.subsystem.power.RebPowerSupplyMain
 
init() - Method in class org.lsst.ccs.subsystem.power.RebPowerSupplyNode
 
init() - Method in class org.lsst.ccs.subsystem.power.SimPowerDevice
Initialization
initChannel(Channel) - Method in class org.lsst.ccs.subsystem.power.EpduG3Device
Initializes a monitoring channel (checks validity)
initChannel(Channel) - Method in class org.lsst.ccs.subsystem.power.RebPsDevice
 
initChannel(Channel) - Method in class org.lsst.ccs.subsystem.power.RebPsDeviceOld
Initializes a monitoring channel.
initDevice() - Method in class org.lsst.ccs.subsystem.power.BfrComCamDevice
Performs configuration.
initDevice() - Method in class org.lsst.ccs.subsystem.power.BfrDevice
Performs configuration.
initDevice() - Method in class org.lsst.ccs.subsystem.power.CpfeDevice
Performs basic initialization.
initDevice() - Method in class org.lsst.ccs.subsystem.power.EpduG3Device
Performs configuration.
initDevice() - Method in class org.lsst.ccs.subsystem.power.PduCommonDevice
Performs configuration.
initDevice() - Method in class org.lsst.ccs.subsystem.power.PowerDevice
Performs configuration.
initDevice() - Method in class org.lsst.ccs.subsystem.power.QbMaq20Device
Device initialization - checks configuration.
initDevice() - Method in class org.lsst.ccs.subsystem.power.RebBulkPsDevice
Performs configuration.
initDevice() - Method in class org.lsst.ccs.subsystem.power.RebPsDevice
 
initDevice() - Method in class org.lsst.ccs.subsystem.power.RebPsDeviceOld
Performs configuration checking.
initialize() - Method in class org.lsst.ccs.subsystem.power.BfrComCamDevice
Performs full initialization.
initialize() - Method in class org.lsst.ccs.subsystem.power.BfrDevice
Performs full initialization.
initialize() - Method in class org.lsst.ccs.subsystem.power.EpduG3Device
Performs full initialization.
initialize() - Method in class org.lsst.ccs.subsystem.power.PduCommonDevice
Performs full initialization.
initialize() - Method in class org.lsst.ccs.subsystem.power.PowerDevice
Performs full initialization.
initialize() - Method in class org.lsst.ccs.subsystem.power.RebBulkPsDevice
Performs full initialization.
initialize() - Method in class org.lsst.ccs.subsystem.power.RebPsDevice
 
initialize() - Method in class org.lsst.ccs.subsystem.power.RebPsDeviceOld
Performs full initialization.
isCornerRaft() - Method in class org.lsst.ccs.subsystem.power.PowerSupplyConfiguration
 
isDphiOn() - Method in class org.lsst.ccs.subsystem.power.ATSPowerMain
Queries the DPHI voltage state.
isHvBiasOn() - Method in class org.lsst.ccs.subsystem.power.ATSPowerMain
Queries the HV bias voltage state.
isSwitchOn(int) - Method in class org.lsst.ccs.subsystem.power.BfrComCamDevice
Gets the state of a relay.
isSwitchOn(int) - Method in class org.lsst.ccs.subsystem.power.BfrDevice
Gets the state of a relay.
isSwitchOn(int) - Method in class org.lsst.ccs.subsystem.power.PduCommonDevice
Gets the state of a PDU channel.
isSwitchOn(int) - Method in class org.lsst.ccs.subsystem.power.QbMaq20Device
Gets the on state of a switch.
isSwitchOn(int) - Method in class org.lsst.ccs.subsystem.power.RebBulkPsDevice
Gets the state of a bulk power supply.
isSwitchOn(int) - Method in interface org.lsst.ccs.subsystem.power.SwitchControl
 

K

Keithley2231Device - Class in org.lsst.ccs.subsystem.power
Interface to a Keithley model 2231A power supply device.
Keithley2231Device() - Constructor for class org.lsst.ccs.subsystem.power.Keithley2231Device
Constructor.

L

LOG - Static variable in class org.lsst.ccs.subsystem.power.PduCommonDevice
Constants.
LOG - Static variable in class org.lsst.ccs.subsystem.power.PowerDevice
Constants.
LOG - Static variable in class org.lsst.ccs.subsystem.power.PowerGroup
Constants.
LOG - Static variable in class org.lsst.ccs.subsystem.power.RebPowerSupplyNode
 

M

MainPower - Class in org.lsst.ccs.subsystem.power
Implements the power supply control subsystem.
MainPower() - Constructor for class org.lsst.ccs.subsystem.power.MainPower
Constructor
MON_TYPE_BOARD_TEMP - Static variable in class org.lsst.ccs.subsystem.power.RebBulkPsDevice
 
MON_TYPE_CURRENT - Static variable in class org.lsst.ccs.subsystem.power.PduCommonDevice
 
MON_TYPE_CURRENT - Static variable in class org.lsst.ccs.subsystem.power.RebBulkPsDevice
 
MON_TYPE_TEMP - Static variable in class org.lsst.ccs.subsystem.power.RebBulkPsDevice
 
MON_TYPE_VOLTAGE - Static variable in class org.lsst.ccs.subsystem.power.PduCommonDevice
 
MON_TYPE_VOLTAGE - Static variable in class org.lsst.ccs.subsystem.power.RebBulkPsDevice
 

N

N6487Device - Class in org.lsst.ccs.subsystem.power
Interface to a Keithley N6487 power supply device.
N6487Device() - Constructor for class org.lsst.ccs.subsystem.power.N6487Device
Constructor.
N6700Device - Class in org.lsst.ccs.subsystem.power
Interface to an Agilent N6700 power supply device.
N6700Device() - Constructor for class org.lsst.ccs.subsystem.power.N6700Device
Constructor.
name - Variable in class org.lsst.ccs.subsystem.power.PowerControl
Data fields.
NETWORK_CONN_INVALID - Static variable in class org.lsst.ccs.subsystem.power.PowerDevice
 
node - Variable in class org.lsst.ccs.subsystem.power.PduCommonDevice
Data fields.
node - Variable in class org.lsst.ccs.subsystem.power.RebBulkPsDevice
Data fields.

O

onStatusMessage(StatusMessage) - Method in class org.lsst.ccs.subsystem.power.ComCamQuadBox
Handles vacuum status messages.
opened() - Method in class org.lsst.ccs.subsystem.power.RebPower
Called when a power supply device is opened.
opened() - Method in interface org.lsst.ccs.subsystem.power.RebPsDevice.Event
 
opened() - Method in interface org.lsst.ccs.subsystem.power.RebPsDeviceOld.Event
 
org.lsst.ccs.subsystem.power - package org.lsst.ccs.subsystem.power
 
otmOff() - Method in class org.lsst.ccs.subsystem.power.ATSPowerMain
Turns off the OTM power.
otmOn() - Method in class org.lsst.ccs.subsystem.power.ATSPowerMain
Turns on the OTM power.

P

PathFinderQuadBox - Class in org.lsst.ccs.subsystem.power
Implements the Quad Box control subsystem.
PathFinderQuadBox() - Constructor for class org.lsst.ccs.subsystem.power.PathFinderQuadBox
Constructor.
pDevc - Variable in class org.lsst.ccs.subsystem.power.PowerControl
 
Pdu24vcDevice - Class in org.lsst.ccs.subsystem.power
Interface to a SLAC 24V clean PDU.
Pdu24vcDevice() - Constructor for class org.lsst.ccs.subsystem.power.Pdu24vcDevice
 
Pdu24vdDevice - Class in org.lsst.ccs.subsystem.power
Interface to a SLAC 24V dirty PDU.
Pdu24vdDevice() - Constructor for class org.lsst.ccs.subsystem.power.Pdu24vdDevice
 
Pdu48vDevice - Class in org.lsst.ccs.subsystem.power
Interface to a SLAC 48V (dirty) PDU.
Pdu48vDevice() - Constructor for class org.lsst.ccs.subsystem.power.Pdu48vDevice
 
Pdu5vDevice - Class in org.lsst.ccs.subsystem.power
Interface to a SLAC 5V PDU.
Pdu5vDevice() - Constructor for class org.lsst.ccs.subsystem.power.Pdu5vDevice
 
PduCommonDevice - Class in org.lsst.ccs.subsystem.power
Interface to a SLAC PDU.
PduCommonDevice(PduCommon, String, int) - Constructor for class org.lsst.ccs.subsystem.power.PduCommonDevice
Constructor.
PduHvDevice - Class in org.lsst.ccs.subsystem.power
Interface to a SLAC HV PDU.
PduHvDevice(PduHV, String, int) - Constructor for class org.lsst.ccs.subsystem.power.PduHvDevice
Constructor.
periodicBroadcast() - Method in class org.lsst.ccs.subsystem.power.ComCamQuadBox
Performs periodic power data broadcast.
periodicBroadcast() - Method in class org.lsst.ccs.subsystem.power.MainPower
Performs periodic power data broadcast.
periodicBroadcast() - Method in class org.lsst.ccs.subsystem.power.PathFinderQuadBox
Performs periodic power data broadcast.
postInit() - Method in class org.lsst.ccs.subsystem.power.ATSPowerMain
Power subsystem post-initialization
postInit() - Method in class org.lsst.ccs.subsystem.power.ComCamQuadBox
Subsystem post-initialization
postInit() - Method in class org.lsst.ccs.subsystem.power.MainPower
Power subsystem post-initialization
postInit() - Method in class org.lsst.ccs.subsystem.power.PathFinderQuadBox
Subsystem post-initialization
postInit() - Method in class org.lsst.ccs.subsystem.power.QuadBox
Subsystem post-initialization
postInit() - Method in class org.lsst.ccs.subsystem.power.RebPower
Initializes the power subsystem.
postStart() - Method in class org.lsst.ccs.subsystem.power.ATSPowerMain
Starts the subsystem.
postStart() - Method in class org.lsst.ccs.subsystem.power.ComCamQuadBox
Starts the subsystem.
postStart() - Method in class org.lsst.ccs.subsystem.power.EatonPdus
Starts the subsystem.
postStart() - Method in class org.lsst.ccs.subsystem.power.MainPower
Starts the subsystem.
postStart() - Method in class org.lsst.ccs.subsystem.power.PathFinderQuadBox
Starts the subsystem.
postStart() - Method in class org.lsst.ccs.subsystem.power.QuadBox
Starts the subsystem.
postStart() - Method in class org.lsst.ccs.subsystem.power.RebPower
Starts the subsystem.
PowerControl - Class in org.lsst.ccs.subsystem.power
Implements power supply control functions.
PowerControl() - Constructor for class org.lsst.ccs.subsystem.power.PowerControl
 
PowerControlOld - Class in org.lsst.ccs.subsystem.power
Implements power supply control functions.
PowerControlOld() - Constructor for class org.lsst.ccs.subsystem.power.PowerControlOld
 
PowerDevice - Class in org.lsst.ccs.subsystem.power
Interface to an ASCII-commanded power supply device.
PowerDevice(String, PowerSupplyDriver, int, int, int) - Constructor for class org.lsst.ccs.subsystem.power.PowerDevice
Constructor.
PowerDevice(String, PowerSupplyDriver, DriverConstants.ConnType, String, int, int, int, int) - Constructor for class org.lsst.ccs.subsystem.power.PowerDevice
Constructor.
PowerDeviceGroup - Class in org.lsst.ccs.subsystem.power
Interface to an ASCII-commanded power supply device.
PowerDeviceGroup() - Constructor for class org.lsst.ccs.subsystem.power.PowerDeviceGroup
 
PowerGroup - Class in org.lsst.ccs.subsystem.power
Implements a power supply control channel group.
PowerGroup(PowerControl...) - Constructor for class org.lsst.ccs.subsystem.power.PowerGroup
Constructor.
powerOff() - Method in class org.lsst.ccs.subsystem.power.ATSPowerMain
Turns off all the REB power.
powerOff() - Method in class org.lsst.ccs.subsystem.power.MainPower
Turns off the power.
powerOff() - Method in class org.lsst.ccs.subsystem.power.PowerDeviceGroup
Powers off all channels.
powerOff() - Method in class org.lsst.ccs.subsystem.power.PowerGroup
Powers off all channels.
powerOffAllRebs() - Method in class org.lsst.ccs.subsystem.power.RebPowerSupplyMain
 
powerOn() - Method in class org.lsst.ccs.subsystem.power.ATSPowerMain
Turns on the REB power, except for HV bias.
powerOn() - Method in class org.lsst.ccs.subsystem.power.MainPower
Turns on the power.
powerOn() - Method in class org.lsst.ccs.subsystem.power.PowerDeviceGroup
Powers on all channels.
powerOn() - Method in class org.lsst.ccs.subsystem.power.PowerGroup
Powers on all channels.
powerRebOff() - Method in class org.lsst.ccs.subsystem.power.RebPowerSupplyNode
 
powerRebOn() - Method in class org.lsst.ccs.subsystem.power.RebPowerSupplyNode
 
PowerSupplyConfiguration - Class in org.lsst.ccs.subsystem.power
A class with the configuration for a given Power Supply.
powerSupplyConfiguration - Variable in class org.lsst.ccs.subsystem.power.RebPowerSupplyNode
 
powerSupplyDevice - Variable in class org.lsst.ccs.subsystem.power.RebPowerSupplyNode
 
PROPERTIES_PREFIX - Static variable in class org.lsst.ccs.subsystem.power.RebPowerSupplyWiring
 
psd - Variable in class org.lsst.ccs.subsystem.power.PowerDevice
 
psPath - Variable in class org.lsst.ccs.subsystem.power.RebPsDevice
 
psPath - Variable in class org.lsst.ccs.subsystem.power.RebPsDeviceOld
 
publishState() - Method in class org.lsst.ccs.subsystem.power.QuadBox
Publishes the state of the quad box system.

Q

QbMaq20Device - Class in org.lsst.ccs.subsystem.power
Handles MAQ20 DIOL modules.
QbMaq20Device() - Constructor for class org.lsst.ccs.subsystem.power.QbMaq20Device
 
QuadBox - Class in org.lsst.ccs.subsystem.power
Implements the Quad Box control subsystem.
QuadBox() - Constructor for class org.lsst.ccs.subsystem.power.QuadBox
Constructor.

R

readChanExtrema(int, RebPsDevice.PsName, RebPsDevice.ChanName) - Method in class org.lsst.ccs.subsystem.power.RebPsDevice
Reads extrema for a power supply channel
readChanExtrema(int, RebPsDeviceOld.PsName, RebPsDeviceOld.ChanName) - Method in class org.lsst.ccs.subsystem.power.RebPsDeviceOld
Reads extrema for a power supply channel
readChannel(Channel) - Method in class org.lsst.ccs.subsystem.power.BfrComCamDevice
Reads a monitored channel.
readChannel(Channel) - Method in class org.lsst.ccs.subsystem.power.BfrDevice
Reads a monitored channel.
readChannel(Channel) - Method in class org.lsst.ccs.subsystem.power.CpfeDevice
Reads a channel.
readChannel(Channel) - Method in class org.lsst.ccs.subsystem.power.EpduG3Device
Reads a monitoring channel.
readChannel(Channel) - Method in class org.lsst.ccs.subsystem.power.PduCommonDevice
Reads a monitoring channel.
readChannel(Channel) - Method in class org.lsst.ccs.subsystem.power.PduHvDevice
Reads a monitoring channel.
readChannel(Channel) - Method in class org.lsst.ccs.subsystem.power.PowerDevice
Reads a monitoring channel.
readChannel(Channel) - Method in class org.lsst.ccs.subsystem.power.RebBulkPsDevice
Reads a monitoring channel.
readChannel(Channel) - Method in class org.lsst.ccs.subsystem.power.RebPsDevice
 
readChannel(Channel) - Method in class org.lsst.ccs.subsystem.power.RebPsDeviceOld
Reads a monitoring channel.
readChannelGroup(String) - Method in class org.lsst.ccs.subsystem.power.BfrComCamDevice
Reads all monitored channels.
readChannelGroup(String) - Method in class org.lsst.ccs.subsystem.power.BfrDevice
Reads all monitored channels.
readCurrent(int) - Method in class org.lsst.ccs.subsystem.power.BK9130GroupDevice
Reads the current from the hardware.
readCurrent() - Method in class org.lsst.ccs.subsystem.power.PowerControl
Reads the current from the hardware.
readCurrent(int) - Method in class org.lsst.ccs.subsystem.power.PowerDevice
Reads the current from the hardware.
readCurrentGroup() - Method in class org.lsst.ccs.subsystem.power.BK9130GroupDevice
Reads all the currents from the hardware.
readCurrentGroup() - Method in class org.lsst.ccs.subsystem.power.PowerDevice
Reads a group of currents from the hardware.
readDphiDac() - Method in class org.lsst.ccs.subsystem.power.CornerRaftRebPowerSupplyNode
 
readHvBiasDac() - Method in class org.lsst.ccs.subsystem.power.RebPowerSupplyNode
 
readOutput(int) - Method in class org.lsst.ccs.subsystem.power.BK9130GroupDevice
Reads the power output state from the hardware.
readOutput() - Method in class org.lsst.ccs.subsystem.power.PowerControl
Reads the power output state from the hardware.
readOutput(int) - Method in class org.lsst.ccs.subsystem.power.PowerDevice
Reads the power output state from the hardware.
readOutputGroup() - Method in class org.lsst.ccs.subsystem.power.BK9130GroupDevice
Reads all the output states from the hardware.
readOutputGroup() - Method in class org.lsst.ccs.subsystem.power.PowerDevice
Reads a group of power output states from the hardware.
readRegs(int, int) - Method in class org.lsst.ccs.subsystem.power.RebPsDevice
 
readVoltage(int) - Method in class org.lsst.ccs.subsystem.power.BK9130GroupDevice
Reads the voltage from the hardware.
readVoltage() - Method in class org.lsst.ccs.subsystem.power.PowerControl
Reads the voltage from the hardware.
readVoltage(int) - Method in class org.lsst.ccs.subsystem.power.PowerDevice
Reads the voltage from the hardware.
readVoltageGroup() - Method in class org.lsst.ccs.subsystem.power.BK9130GroupDevice
Reads all the voltages from the hardware.
readVoltageGroup() - Method in class org.lsst.ccs.subsystem.power.PowerDevice
Reads a group of voltages from the hardware.
RebBulkPsDevice - Class in org.lsst.ccs.subsystem.power
Interface to the SLAC REB bulk PS controller.
RebBulkPsDevice() - Constructor for class org.lsst.ccs.subsystem.power.RebBulkPsDevice
 
rebName - Variable in class org.lsst.ccs.subsystem.power.RebPowerSupplyNode
 
rebPath - Variable in class org.lsst.ccs.subsystem.power.RebPowerSupplyNode
 
RebPower - Class in org.lsst.ccs.subsystem.power
Implements the REB PS control subsystem.
RebPower() - Constructor for class org.lsst.ccs.subsystem.power.RebPower
Constructor
RebPowerAlarm - Class in org.lsst.ccs.subsystem.power
An Alarm class for a given Reb.
RebPowerAlarm() - Constructor for class org.lsst.ccs.subsystem.power.RebPowerAlarm
 
RebPowerSupplyMain - Class in org.lsst.ccs.subsystem.power
Implements the REB PS control subsystem.
RebPowerSupplyMain() - Constructor for class org.lsst.ccs.subsystem.power.RebPowerSupplyMain
 
RebPowerSupplyNode - Class in org.lsst.ccs.subsystem.power
A class representing an individual Reb.
RebPowerSupplyNode(PowerSupplyConfiguration, int) - Constructor for class org.lsst.ccs.subsystem.power.RebPowerSupplyNode
 
RebPowerSupplyWiring - Class in org.lsst.ccs.subsystem.power
A class to control the Reb Power Supplies wiring via build configuration properties.
RebPowerSupplyWiring(Properties) - Constructor for class org.lsst.ccs.subsystem.power.RebPowerSupplyWiring
 
RebPsBoardAlarm - Class in org.lsst.ccs.subsystem.power
An Alarm class for raising alerts specific to a given RebPs.
RebPsBoardAlarm() - Constructor for class org.lsst.ccs.subsystem.power.RebPsBoardAlarm
 
RebPsControl - Class in org.lsst.ccs.subsystem.power
Implements REB power supply control functions.
RebPsControl(String, int) - Constructor for class org.lsst.ccs.subsystem.power.RebPsControl
Constructor.
RebPsDevice - Class in org.lsst.ccs.subsystem.power
Interface to a REB power supply board.
RebPsDevice() - Constructor for class org.lsst.ccs.subsystem.power.RebPsDevice
 
RebPsDevice.ChanName - Enum in org.lsst.ccs.subsystem.power
 
RebPsDevice.Event - Interface in org.lsst.ccs.subsystem.power
Interface for open/close event listener.
RebPsDevice.PsName - Enum in org.lsst.ccs.subsystem.power
Public constants.
RebPsDeviceOld - Class in org.lsst.ccs.subsystem.power
Interface to a REB power supply board.
RebPsDeviceOld() - Constructor for class org.lsst.ccs.subsystem.power.RebPsDeviceOld
 
RebPsDeviceOld.ChanName - Enum in org.lsst.ccs.subsystem.power
 
RebPsDeviceOld.Event - Interface in org.lsst.ccs.subsystem.power
Interface for open/close event listener.
RebPsDeviceOld.PsName - Enum in org.lsst.ccs.subsystem.power
Public constants.
RebTrippedState - Class in org.lsst.ccs.subsystem.power
A class representing the tripped status for a Reb.
resetChanExtrema(int, RebPsDeviceOld.PsName, RebPsDeviceOld.ChanName) - Method in class org.lsst.ccs.subsystem.power.RebPower
Resets the maximum and minimum values of a channel.
resetChanExtrema(RebPsDevice.PsName, RebPsDevice.ChanName) - Method in class org.lsst.ccs.subsystem.power.RebPowerSupplyNode
Resets the maximum and minimum values of a channel.
resetChanExtrema(int, RebPsDevice.PsName, RebPsDevice.ChanName) - Method in class org.lsst.ccs.subsystem.power.RebPsDevice
Resets extrema for a power supply channel
resetChanExtrema(int, RebPsDeviceOld.PsName, RebPsDeviceOld.ChanName) - Method in class org.lsst.ccs.subsystem.power.RebPsDeviceOld
Resets extrema for a power supply channel

S

saveNamedConfig(String) - Method in class org.lsst.ccs.subsystem.power.MainPower
Saves the configuration data.
sequencePower(int, boolean) - Method in class org.lsst.ccs.subsystem.power.RebPower
Sequences a power supply on or off.
sequencePower(int, boolean) - Method in class org.lsst.ccs.subsystem.power.RebPsDevice
Sequences a power supply section on or off.
sequencePower(boolean) - Method in class org.lsst.ccs.subsystem.power.RebPsDevice
Sequences a whole power supply on or off.
sequencePower(int, boolean) - Method in class org.lsst.ccs.subsystem.power.RebPsDeviceOld
Sequences a power supply section on or off.
sequencePower(boolean) - Method in class org.lsst.ccs.subsystem.power.RebPsDeviceOld
Sequences a whole power supply on or off.
setBiasDac(int, double) - Method in class org.lsst.ccs.subsystem.power.RebPower
Sets a HV bias DAC value.
setBiasDac(int, double) - Method in class org.lsst.ccs.subsystem.power.RebPsDevice
Sets a HV bias DAC value.
setBiasDac(int, double) - Method in class org.lsst.ccs.subsystem.power.RebPsDeviceOld
Sets a HV bias DAC value.
setConsecutiveExceptiionsToOffline(int) - Method in class org.lsst.ccs.subsystem.power.RebPsDevice
Set the number of consecutive exceptions that will put the device offline.
setCurrent(double) - Method in class org.lsst.ccs.subsystem.power.PowerControl
Sets the current.
setCurrent(double) - Method in class org.lsst.ccs.subsystem.power.PowerControlOld
Sets/gets the current.
setDphi(double) - Method in class org.lsst.ccs.subsystem.power.ATSPowerMain
Sets the DPHI voltage
setDphi(int) - Method in class org.lsst.ccs.subsystem.power.CornerRaftRebPowerSupplyNode
 
setDphiDac(int, double) - Method in class org.lsst.ccs.subsystem.power.RebPower
Sets a DPHI DAC value.
setDphiDac(int, double) - Method in class org.lsst.ccs.subsystem.power.RebPsDevice
Sets a DPHI DAC value.
setDphiDac(int, double) - Method in class org.lsst.ccs.subsystem.power.RebPsDeviceOld
Sets a DPHI DAC value.
setHvBias(double) - Method in class org.lsst.ccs.subsystem.power.ATSPowerMain
Sets the HV bias voltage
setHVBias(int) - Method in class org.lsst.ccs.subsystem.power.RebPowerSupplyNode
 
setListener(RebPsDevice.Event) - Method in class org.lsst.ccs.subsystem.power.RebPsDevice
Sets an event listener.
setListener(RebPsDeviceOld.Event) - Method in class org.lsst.ccs.subsystem.power.RebPsDeviceOld
Sets an event listener.
setMainPower(boolean) - Method in class org.lsst.ccs.subsystem.power.RebPower
Turns the main power supply on or off.
setMaxChannel(int) - Method in class org.lsst.ccs.subsystem.power.PowerDevice
Sets the maximum channel number.
setMinChannel(int) - Method in class org.lsst.ccs.subsystem.power.PowerDevice
Sets the minimum channel number.
setNamedPowerOn(int, RebPsEnum, boolean) - Method in class org.lsst.ccs.subsystem.power.RebPower
Turns a power supply on or off.
setNamedSwitchOn(String, boolean) - Method in class org.lsst.ccs.subsystem.power.ComCamQuadBox
Turns a named switch on or off.
setNamedSwitchOn(String, boolean) - Method in class org.lsst.ccs.subsystem.power.PathFinderQuadBox
Turns a named switch on or off.
setOffDelay(double) - Method in class org.lsst.ccs.subsystem.power.PowerControl
Sets the power-off delay.
setOffDelay(double) - Method in class org.lsst.ccs.subsystem.power.PowerControlOld
Sets/gets the power-off delay.
setOnDelay(double) - Method in class org.lsst.ccs.subsystem.power.PowerControl
Sets the power-on delay.
setOnDelay(double) - Method in class org.lsst.ccs.subsystem.power.PowerControlOld
Sets/gets the power-on delay.
setOnline(boolean) - Method in class org.lsst.ccs.subsystem.power.RebPsDevice
 
setPowerConfig(Power[]) - Method in class org.lsst.ccs.subsystem.power.MainPower
Sets the configuration data.
setPowerConfig(Power) - Method in class org.lsst.ccs.subsystem.power.PowerDeviceGroup
Sets the configuration data.
setPowerOn(int, int, boolean) - Method in class org.lsst.ccs.subsystem.power.RebPower
Turns a power supply on or off.
setPowerOn(int, int, boolean) - Method in class org.lsst.ccs.subsystem.power.RebPsDevice
Turns a power supply on or off.
setPowerOn(int, int, boolean) - Method in class org.lsst.ccs.subsystem.power.RebPsDeviceOld
Turns a power supply on or off.
setPsDeviceConsecutiveExceptionsToOffline(int) - Method in class org.lsst.ccs.subsystem.power.RebPowerSupplyMain
 
setPsDeviceReadTimeout(long) - Method in class org.lsst.ccs.subsystem.power.RebPowerSupplyMain
 
setReadTimeout(long) - Method in class org.lsst.ccs.subsystem.power.RebPsDevice
Set the timeout for the underlying driver.
setSimulatedRebPower(String, double) - Method in class org.lsst.ccs.subsystem.power.RebPower
Sets the simulated REB power
setSwitchOn(int, boolean) - Method in class org.lsst.ccs.subsystem.power.ComCamQuadBox
Turns a switch on or off.
setSwitchOn(int, boolean) - Method in class org.lsst.ccs.subsystem.power.PathFinderQuadBox
Turns a switch on or off.
setSwitchOn(String, boolean) - Method in class org.lsst.ccs.subsystem.power.QuadBox
Turns a switch on or off.
setUpdatePeriod(int) - Method in class org.lsst.ccs.subsystem.power.ComCamQuadBox
Sets the update (tick) period.
setUpdatePeriod(int) - Method in class org.lsst.ccs.subsystem.power.MainPower
Sets the update (tick) period.
setUpdatePeriod(int) - Method in class org.lsst.ccs.subsystem.power.PathFinderQuadBox
Sets the update (tick) period.
setUpdatePeriod(int) - Method in class org.lsst.ccs.subsystem.power.RebPower
Sets the update (tick) period.
setVoltage(double) - Method in class org.lsst.ccs.subsystem.power.PowerControl
Sets the voltage.
setVoltage(double) - Method in class org.lsst.ccs.subsystem.power.PowerControlOld
Sets/gets the voltage.
shutdown() - Method in class org.lsst.ccs.subsystem.power.BulkPSEmergencyResponseManager
 
shutdown() - Method in class org.lsst.ccs.subsystem.power.EmergencyResponseManager
 
SimPowerDevice - Class in org.lsst.ccs.subsystem.power
Implementation of a simulated power supply device.
SimPowerDevice() - Constructor for class org.lsst.ccs.subsystem.power.SimPowerDevice
Constructor.
start() - Method in class org.lsst.ccs.subsystem.power.BulkPSEmergencyResponseManager
 
start() - Method in class org.lsst.ccs.subsystem.power.EmergencyResponseManager
 
SwitchControl - Interface in org.lsst.ccs.subsystem.power
Interface for controlling switches.
switchOff(int) - Method in class org.lsst.ccs.subsystem.power.BfrComCamDevice
Turns a relay off.
switchOff(int) - Method in class org.lsst.ccs.subsystem.power.BfrDevice
Turns a relay off.
switchOff(int) - Method in class org.lsst.ccs.subsystem.power.PduCommonDevice
Turns a PDU channel off.
switchOff(int) - Method in class org.lsst.ccs.subsystem.power.QbMaq20Device
Sets a switch off.
switchOff(int) - Method in class org.lsst.ccs.subsystem.power.RebBulkPsDevice
Turns a bulk power supply off.
switchOff(int) - Method in interface org.lsst.ccs.subsystem.power.SwitchControl
 
switchOn(int) - Method in class org.lsst.ccs.subsystem.power.BfrComCamDevice
Turns a relay on.
switchOn(int) - Method in class org.lsst.ccs.subsystem.power.BfrDevice
Turns a relay on.
switchOn(int) - Method in class org.lsst.ccs.subsystem.power.PduCommonDevice
Turns a PDU channel on.
switchOn(int) - Method in class org.lsst.ccs.subsystem.power.QbMaq20Device
Sets a switch on.
switchOn(int) - Method in class org.lsst.ccs.subsystem.power.RebBulkPsDevice
Turns a bulk power supply on.
switchOn(int) - Method in interface org.lsst.ccs.subsystem.power.SwitchControl
 

T

toggleMainPower() - Method in class org.lsst.ccs.subsystem.power.RebPower
Toggles the main power supply state.
toggleNamedPower(int, RebPsEnum) - Method in class org.lsst.ccs.subsystem.power.RebPower
Toggles the on/off state of a power supply.
togglePower(int, int) - Method in class org.lsst.ccs.subsystem.power.RebPower
Toggles the on/off state of a power supply.
togglePower(int, int) - Method in class org.lsst.ccs.subsystem.power.RebPsDevice
Toggles the on/off state of a power supply.
togglePower(int, int) - Method in class org.lsst.ccs.subsystem.power.RebPsDeviceOld
Toggles the on/off state of a power supply.

V

valueOf(String) - Static method in enum org.lsst.ccs.subsystem.power.RebPsDevice.ChanName
Returns the enum constant of this type with the specified name.
valueOf(String) - Static method in enum org.lsst.ccs.subsystem.power.RebPsDevice.PsName
Returns the enum constant of this type with the specified name.
valueOf(String) - Static method in enum org.lsst.ccs.subsystem.power.RebPsDeviceOld.ChanName
Returns the enum constant of this type with the specified name.
valueOf(String) - Static method in enum org.lsst.ccs.subsystem.power.RebPsDeviceOld.PsName
Returns the enum constant of this type with the specified name.
values() - Static method in enum org.lsst.ccs.subsystem.power.RebPsDevice.ChanName
Returns an array containing the constants of this enum type, in the order they are declared.
values() - Static method in enum org.lsst.ccs.subsystem.power.RebPsDevice.PsName
Returns an array containing the constants of this enum type, in the order they are declared.
values() - Static method in enum org.lsst.ccs.subsystem.power.RebPsDeviceOld.ChanName
Returns an array containing the constants of this enum type, in the order they are declared.
values() - Static method in enum org.lsst.ccs.subsystem.power.RebPsDeviceOld.PsName
Returns an array containing the constants of this enum type, in the order they are declared.

W

waitPowerOff(int) - Method in class org.lsst.ccs.subsystem.power.PowerDeviceGroup
Waits for power-off to complete.
waitPowerOff(int) - Method in class org.lsst.ccs.subsystem.power.PowerGroup
Waits for power-off to complete.
waitPowerOn(int) - Method in class org.lsst.ccs.subsystem.power.PowerDeviceGroup
Waits for power-on to complete.
waitPowerOn(int) - Method in class org.lsst.ccs.subsystem.power.PowerGroup
Waits for power-on to complete.
writeAll() - Method in class org.lsst.ccs.subsystem.power.PowerControl
Writes all set quantities to the hardware.
writeCurrent(double, int) - Method in class org.lsst.ccs.subsystem.power.BK9130GroupDevice
Writes the current to the hardware.
writeCurrent() - Method in class org.lsst.ccs.subsystem.power.PowerControl
Writes the current to the hardware.
writeCurrent(double, int) - Method in class org.lsst.ccs.subsystem.power.PowerDevice
Writes the current to the hardware.
writeCurrentGroup() - Method in class org.lsst.ccs.subsystem.power.BK9130GroupDevice
Writes all the currents to the hardware.
writeCurrentGroup() - Method in class org.lsst.ccs.subsystem.power.PowerDevice
Writes a group of currents to the hardware.
writeOffDelay() - Method in class org.lsst.ccs.subsystem.power.PowerControl
Writes the power-off delay to the hardware.
writeOffDelay(double, int) - Method in class org.lsst.ccs.subsystem.power.PowerDevice
Writes the power-off delay to the hardware.
writeOffDelayGroup() - Method in class org.lsst.ccs.subsystem.power.PowerDevice
Writes a group of power-off delays to the hardware.
writeOnDelay() - Method in class org.lsst.ccs.subsystem.power.PowerControl
Writes the power-on delay to the hardware.
writeOnDelay(double, int) - Method in class org.lsst.ccs.subsystem.power.PowerDevice
Writes the power-on delay to the hardware.
writeOnDelayGroup() - Method in class org.lsst.ccs.subsystem.power.PowerDevice
Writes a group of power-on delays to the hardware.
writeOutput(boolean, int) - Method in class org.lsst.ccs.subsystem.power.BK9130GroupDevice
Writes the power output state to the hardware.
writeOutput(boolean) - Method in class org.lsst.ccs.subsystem.power.PowerControl
Writes the power output state to the hardware.
writeOutput(boolean, int) - Method in class org.lsst.ccs.subsystem.power.PowerDevice
Writes the power output state to the hardware.
writeOutputGroup() - Method in class org.lsst.ccs.subsystem.power.BK9130GroupDevice
Writes all the output states to the hardware.
writeOutputGroup() - Method in class org.lsst.ccs.subsystem.power.PowerDevice
Writes a group of power output states to the hardware.
writeVoltage(double, int) - Method in class org.lsst.ccs.subsystem.power.BK9130GroupDevice
Writes the voltage to the hardware.
writeVoltage() - Method in class org.lsst.ccs.subsystem.power.PowerControl
Writes the voltage to the hardware.
writeVoltage(double, int) - Method in class org.lsst.ccs.subsystem.power.PowerDevice
Writes the voltage to the hardware.
writeVoltageGroup() - Method in class org.lsst.ccs.subsystem.power.BK9130GroupDevice
Writes all the voltages to the hardware.
writeVoltageGroup() - Method in class org.lsst.ccs.subsystem.power.PowerDevice
Writes a group of voltages to the hardware.
A B C D E F G H I K L M N O P Q R S T V W 
Skip navigation links

Copyright © 2024 LSST. All rights reserved.