public class Loader extends Object implements org.lsst.ccs.framework.HardwareController, FilterHolder, AlertRaiser, org.lsst.ccs.framework.HasLifecycle
alertSeparater| Constructor and Description |
|---|
Loader() |
| Modifier and Type | Method and Description |
|---|---|
void |
checkClosedOnVoid() |
void |
checkConditionsForCarrierMotion(int targetPosition)
Checks if the loader carrier can move.
|
void |
checkConditionsForOpeningHooks()
Check if the clamp can be opened.
|
void |
checkConditionsForUnclampingHooks() |
void |
checkConnectedOnCamera()
Check if loader is connected on camera.
|
void |
checkHaltRequired() |
void |
checkLoaderNotEmpty()
Check if the clamp can be closed.
|
StatusDataPublishedByLoader |
createStatusDataPublishedByLoader()
Creates an Object to be published on the STATUS bus.
|
org.lsst.ccs.services.alert.AlertService |
getAlertService()
return alertService
|
LoaderCarrier |
getCarrier()
Returns carrier.
|
LoaderClamp |
getClamp()
Returns clamp.
|
String |
getName() |
org.lsst.ccs.Subsystem |
getSubsystem() |
void |
initializeGateway() |
boolean |
isAtHandoff()
This method returns true if the autochanger trucks are at HANDOFF position, false otherwise.
|
boolean |
isAtStandby()
This method returns true if the autochanger trucks are at STANDBY position, false otherwise.
|
boolean |
isAutochangerHoldingFilter()
Return true if the autochanger is holding the filter.
|
boolean |
isConnectedOnCamera()
Returns the boolean field atHandoff.
|
boolean |
isEmpty()
Returns the boolean field empty.
|
boolean |
isHoldingFilter()
Return true if a filter is present and it is held by the loader clamp.
|
boolean |
isInitialized() |
void |
locateHardware()
This command has to be executed after the initialization phase and after
the checkHardware command.
|
void |
moveFilterToHandoff()
move a filter from Storage position or a position between ENGAGED and
STORAGE to HANDOFF position.
|
void |
moveFilterToStorage()
Move a filter from HANDOFF to STORAGE.
|
void |
openClampAndMoveEmptyToStorage()
This command can be executed when loader is at Handoff with a filter.
|
void |
postStart()
Check that plutoGateway is booted and initialize plutoGateway.
|
String |
printHardwareState()
Print list of hardware with initialization information.
|
void |
publishData()
Publish Data on status bus for trending data base and GUIs.
|
void |
updateFCSStateToReady()
Update FCS state and FCS readyness state and publish on the status bus.
|
void |
updateStateAndCheckSensors() |
void |
updateStateWithSensors()
This methods updates the carrier and clamp state in reading all the
sensors.
|
clone, equals, finalize, getClass, hashCode, notify, notifyAll, toString, wait, wait, waitcheckHardware, checkStarted, checkStoppedclearAlarm, raiseAlarm, raiseAlarm, raiseAlarm, raiseAlarm, raiseWarning, raiseWarningpublic org.lsst.ccs.services.alert.AlertService getAlertService()
AlertRaisergetAlertService in interface AlertRaiserpublic String getName()
getName in interface AlertRaiserpublic org.lsst.ccs.Subsystem getSubsystem()
getSubsystem in interface AlertRaiserpublic LoaderCarrier getCarrier()
public LoaderClamp getClamp()
@Command(type=QUERY,
level=0,
description="Return true if hardware (controllers and plutoGateway) is correctly initializedand homing of the controllers is done.")
public boolean isInitialized()
@Command(type=QUERY,
level=0,
description="Return true if there is no filter in the loader. This command doesn\'t read again the sensors.")
public boolean isEmpty()
@Command(type=QUERY,
level=0,
description="Return true if the loader is connected on the camera. This command doesn\'t read again the sensors.")
public boolean isConnectedOnCamera()
@Command(type=QUERY,
level=0,
description="Return true if the autochanger is holding the filter. This command doesn\'t read again the sensors.")
public boolean isAutochangerHoldingFilter()
FcsHardwareException@Command(type=QUERY,
level=0,
description="Return true if a filter is present and it is held by the loader clamp.")
public boolean isHoldingFilter()
isHoldingFilter in interface FilterHolderFcsHardwareException@Command(type=ACTION,
level=1,
description="Attention ! this commands does the homing of the controllers and might move hardware. Initialize loader hardware.",
alias="homing")
public void locateHardware()
public void checkClosedOnVoid()
public void checkHaltRequired()
public void postStart()
postStart in interface org.lsst.ccs.framework.HasLifecyclepublic void initializeGateway()
public void checkConnectedOnCamera()
RejectedCommandException - if not connected on camera@Command(type=QUERY,
level=1,
description="Check if the carrier can move.")
public void checkConditionsForCarrierMotion(int targetPosition)
targetPosition - FcsHardwareExceptionFailedCommandException@Command(type=QUERY,
level=1,
description="Check if the clamp can be opened.")
public void checkConditionsForOpeningHooks()
FcsHardwareExceptionpublic void checkConditionsForUnclampingHooks()
@Command(type=QUERY,
level=1,
description="Check if the clamp can be closed.")
public void checkLoaderNotEmpty()
FcsHardwareExceptionpublic void updateStateAndCheckSensors()
@Command(type=ACTION,
level=1,
description="Update clamp state in reading sensors.")
public void updateStateWithSensors()
updateStateWithSensors in interface FilterHolderFcsHardwareException@Command(type=ACTION,
level=1,
description="Update FCS state and FCS readyness state and publishes on the status bus.")
public void updateFCSStateToReady()
@Command(type=ACTION,
level=1,
description="Move a filter from STORAGE to HANDOFF. This command executes sequence of actions :\n- check initial conditions (a filter, at STORAGE) \n- move carrier to ENGAGED with high speed\n- unclamp filter \n- move slowly filter to HANDOFF. ")
public void moveFilterToHandoff()
@Command(type=ACTION,
level=1)
public void moveFilterToStorage()
@Command(type=ACTION,
level=1,
description="open clamp and move empty to Storage Position at high speed.")
public void openClampAndMoveEmptyToStorage()
public StatusDataPublishedByLoader createStatusDataPublishedByLoader()
public void publishData()
public boolean isAtHandoff()
FilterHolderisAtHandoff in interface FilterHolderpublic boolean isAtStandby()
FilterHolderisAtStandby in interface FilterHolder@Command(type=QUERY,
level=1,
description="Print list of hardware with initialization information.")
public String printHardwareState()
Copyright © 2018 LSST. All rights reserved.